Gravity-Driven, Acoustic-Field-Guided Droplet Addition for 12 h Container-Free Proteomic Processing
Ying Deng, Li Ching Pang, Shuangshuang Zhu, Wei Meng, Oswald Yap Tingzhe, Xueming Dong
Key points
From the paper's conclusion- Here, we implemented gravity-driven, acoustic-field-guided droplet addition in a TinyLev-type device, in which reagent droplets dispensed at lateral distances of up to 3 mm merged with a levitated droplet without needle contact.
Abstract
With advances in analytical sensitivity, low-input samples increasingly require sample-preparation workflows that limit analyte loss during multistep processing. Acoustic levitation (AL) provides a container-free aqueous reaction format. Here, we implemented gravity-driven, acoustic-field-guided droplet addition in a TinyLev-type device, in which reagent droplets dispensed at lateral distances of up to 3 mm merged with a levitated droplet without needle contact. Periodic water replenishment supported 12 h levitation at 37 °C, with 93% Angiotensin II (Ang II) signal retention compared to 53% in low-protein-binding tube. This operational window enabled an approximately 10 h multistep proteomic sample-processing workflow involving 8 h trypsin digestion. Contactless handling produced no detectable residual Ang II peaks in post-exposure blanks, whereas direct needle contact resulted in carryover. Acoustic levitation also provided higher Ang II signal retention than low-protein-binding tube incubation. In proteomic benchmarking, AL yielded higher protein identification counts at 50 and 100 ng, accompanied by higher normalized LFQ variability, particularly at 100 ng. AL also showed higher mean fractions of fully cleaved PSMs and lower mean semi-tryptic PSM fractions at both inputs. A complementary HRP-TMB assay showed a higher concentration−response slope after AL than after conventional microplate incubation. Together, these findings support the use of acoustic levitation as a practical platform for contactless reagent addition and long-duration container-free biochemical processing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acoustic Droplet Ejection High-Resolution Mass Spectrometry Enables High-Throughput Analysis of Proteins in Complex Biologic and Vaccine Matrices.Analytical chemistry · 2026
- An Optimized Protocol for TurboID-Based Proximity Labeling and Sample Preparation for Mass Spectrometry in Arabidopsis thaliana.Bio-protocol · 2026
- SPIN: Inkjet-Driven Nanowell Workflow for Scalable and Sensitive Single-Cell ProteomicsAnalytical Chemistry · 2026
- Transdermal diagnosis and therapy using an integrated acoustofluidic patch.bioRxiv : the preprint server for biology · 2026
- Automated positive-pressure peptide desalting yields equivalent performance to traditional StageTips for TMT and LFQ-based proteomics.Journal of proteomics · 2026
- Interfacial amplifier: High-throughput visual protein detection via droplet dynamics.Science advances · 2026