Journal of proteomics

Automated positive-pressure peptide desalting yields equivalent performance to traditional StageTips for TMT and LFQ-based proteomics.

Ka Yang, Christina B Schroeter, Joao A Paulo

Department of Cell Biology, Harvard Medical School, Boston, MA, USA. · Department of Cell Biology, Harvard Medical School, Boston, MA, USA; Department of Neurology, University Hospital Muenster, Muenster, Germany.

Computational

Key points

From the paper's conclusion
  • We demonstrate that the automated workflow achieves fully equivalent proteome depth, spectral quality, physicochemical peptide recovery, and quantitative accuracy, while reducing hands-on processing time from several hours to under 45 min per 96-well plate.

Abstract

Manual peptide desalting is a frequent bottleneck in high-throughput bottom-up proteomics. We evaluated an automated positive-pressure 96-well solid-phase extraction (SPE) workflow against conventional hand-crafted C18 StageTips in a TMTpro-18plex benchmark comprising nine human cell lines fractionated into 24 high-pH reversed-phase super-fractions. Both workflows achieved essentially equivalent depth (9761 vs 9738 protein groups; 88.6% overlap), with comparable precursor intensities, spectral quality metrics, and chromatographic performance. Quantitative fidelity was preserved, producing near-identical biological segregation by PCA and highly correlated protein-level ratios across cell lines. An independent label-free MaxLFQ benchmark comparing manual vacuum-manifold, automated positive-pressure, and hand-crafted StageTip workflows further showed that automated desalting achieved peptide and protein identification performance comparable to StageTips and yielded the lowest peptide- and protein-level coefficient of variation distributions across replicate preparations. Together, these results support positive-pressure automated desalting as a robust and scalable method for high-throughput proteomics sample preparation that reduces a labor-intensive bottleneck while maintaining proteome coverage and quantitative performance. SIGNIFICANCE: Peptide desalting by manual StageTip solid-phase extraction has been a cornerstone of bottom-up proteomics sample preparation for nearly two decades, yet it remains a throughput bottleneck. It can also be a source of operator-dependent technical variability that can compromise the reproducibility and statistical integrity of large-scale quantitative datasets. Here, we present the first, head-to-head analytical benchmark of the EmporeOmics1000 automated positive-pressure platform against the manual StageTip gold standard. Using both workflows, we evaluated real-world conditions using a 24-fraction TMTpro 18-plex experiment of nine human cell lines. We demonstrate that the automated workflow achieves fully equivalent proteome depth, spectral quality, physicochemical peptide recovery, and quantitative accuracy, while reducing hands-on processing time from several hours to under 45 min per 96-well plate. By removing a major source of labor intensity and inter-operator variability from the proteomics sample preparation pipeline, the automated workflow enables core facilities and high-throughput research programs to process larger clinical cohorts, longitudinal study designs, and highly multiplexed experiments with greater consistency. These findings provide the proteomics community with an evidence-based pathway to modernize and standardize a step that has remained largely manual since its inception, with direct implications for data reproducibility across laboratories.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Automated positive-pressure peptide desalting yields equivalent performance to traditional StageTips for TMT and LFQ-based proteomics — Science Skim