Quantitative Integration of Targeted and Nontargeted Metabolomics Using Multi-Stable Isotope Chemical Tagging with UHPLC-QToF MS: Application to Myeloid Leukemia Metabolism.
Takahiro Takayama, Taiyo Tsutsumi, Tomoya Higuchi, Satoshi Takahashi, Yoshihiro Hayashi, Koichi Inoue
Laboratory of Clinical & Analytical Chemistry, College of Pharmaceutical Sciences, Ritsumeikan University, 1-1-1 Nojihi-gashi, Kusatsu, Shiga525-8577, Japan. · Laboratory of Cancer Pathobiology & Therapeutics, College of Pharmaceutical Sciences, Ritsumeikan University, 1-1-1 Nojihi-gashi, Kusatsu, Shiga525-8577, Japan.
Key points
From the paper's conclusion- These results establish MUSIC not only as a chemical tagging strategy but also as a quantitative measurement framework that approximates analyte-specific response characteristics for integrated targeted and nontargeted metabolomics for amine-containing metabolites.
Abstract
Mass spectrometry-based metabolomics is widely used for comprehensive metabolic profiling. However, most current workflows rely on relative signal intensities, which limit comparability across experiments and prevent quantitative interpretation. This limitation arises from the difficulty in estimating analyte-specific response behavior in the absence of isotopically labeled standards. In this study, we present multistable isotope chemical tagging (MUSIC) as an isotope-resolved internal calibration framework that enables the approximation of response characteristics within a single experimental design. This approach uses multiple isotope-coded tagging reagents as internal calibration points instead of conventional internal standards, enabling the construction of internal calibration curves that account for both tagging efficiency and matrix effects. Internal calibration curves were established for amine-containing metabolites using a dilution series of tagged standard mixtures, enabling robust slope estimation. The resulting calibration framework allows accurate quantification of targeted metabolites and slope-based correction of nontargeted features through reference matching. In validation experiments involving 146 metabolites in serum, the method achieved accuracy and precision within ±15% using only two analytical runs. We further demonstrate that the framework enables the consistent recovery of fold changes across samples and supports comparative metabolic analysis without relying on compound-specific labeled standards. These results establish MUSIC not only as a chemical tagging strategy but also as a quantitative measurement framework that approximates analyte-specific response characteristics for integrated targeted and nontargeted metabolomics for amine-containing metabolites. Following validation, we applied this approach to blood samples to identify the biomarkers of myeloid leukemia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- BrIS: Visualizing Internal Standards at the MS1 Level via Bromine Fingerprint for Sensitive and Robust Proteomics Quality Control.Angewandte Chemie (International ed. in English) · 2026
- MSlineaR: An R Package Assessing Linear Behavior to Improve Quality Assurance and Statistical Robustness in Untargeted Metabolomics.Analytical chemistry · 2026
- Evaluation and correction of charcoal-stripped serum matrix bias in stable-isotope-dilution LC-MS/MS quantification of endogenous serum folates.Analytical and bioanalytical chemistry · 2026
- LC-MS/MS Quantification of Total Milk Protein Allergens: A Dual-Target Approach Using β-Lactoglobulin/β-Casein Standards and Stable Isotope-Labeled Peptide Calibration.Journal of agricultural and food chemistry · 2026
- A Novel Approach for Post-Acquisition Mass Calibration in Metabolomic Profiling by High-Resolution Mass Spectrometry.Advances in experimental medicine and biology · 2026
- A Robust IsotopeRatio LC–MS/MS Workflow forHigh-Throughput Metabolic Profiling of BacteriaAnalytical Chemistry · 2026