Analytical chemistry

Multipass-Enhanced Multicomponent Photoacoustic Gas Sensing with a Hierarchically Coupled H-Type Resonator.

Dong Li, Qinduan Zhang, Jiqiang Wang, Tingting Zhang, Yiwen Feng, Jia Liu, Guo Sun, Minghe Wu,

China-Belarus Belt and Road Joint Laboratory on Intelligent Perception in Extreme Environments/Shandong Key Laboratory of Optoelectronic Sensing Technologies, Laser Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan250014, China. · Key Laboratory of Education Ministry for Laser and Infrared System Integration Technology, Shandong University, 72 Binhai Road, Qingdao266237, China.

Key points

From the paper's conclusion
  • A multipass hierarchically coupled H-type resonator-based photoacoustic sensing system for multicomponent gas detection is proposed.

Abstract

A multipass hierarchically coupled H-type resonator-based photoacoustic sensing system for multicomponent gas detection is proposed. By hierarchically coupling and serially arranging multiple H-type photoacoustic cells (H-PACs), with the reuse of buffer chambers and resonant cavities, several available resonant frequencies are generated at different locations, enabling the highly sensitive detection of three target gases. Furthermore, the incorporation of a multipass cell (MPC) effectively enhances the light-gas interaction, thereby improving the detection performance of the system. Meanwhile, three excitation beams with different wavelengths share a common optical path, significantly increasing the system's integration level. Distributed feedback (DFB) diode lasers with center wavelengths of 1653.72, 1531.58, and 1572.34 nm were employed to selectively excite CH4, C2H2, and CO2, respectively. The experimentally measured resonant frequencies at the three detection positions were 1320, 3515, and 5430 Hz, respectively, showing good agreement with the finite-element simulation results. The introduction of an MPC achieved a photoacoustic (PA) signal enhancement factor of approximately 12.43. The experimental evaluation confirms the reliable quantitative detection performance of CH4, C2H2, and CO2, while no significant cross-interference is observed among the different sensing positions. According to the Allan deviation analysis, minimum detection limits (MDLs) of 21.05 ppb, 4.68 ppb, and 2.63 ppm were achieved for CH4, C2H2, and CO2, respectively, at an averaging time of 300 s.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers