Electrochemical Dual-Sensing Platform for HLA-B*13:01 Detection to Prevent Severe Cutaneous Adverse Reactions (SCARs) Induced by Dapsone and Cotrimoxazole.
Jirapat Attapong, Chollanot Kaset, Nontaya Nakkam, Wichittra Tassaneeyakul, Wichayaporn Kamsong, Chanpen Karuwan, Chonlaphat Sukasem, Sirinart Chomean
Department of Medical Technology, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani12120, Thailand. · Department of Pharmacology, Faculty of Medicine, Khon Kaen University, Khon Kaen40002, Thailand.
Key points
From the paper's conclusion- The HLA-B*13:01 allele is a critical biomarker for dapsone- and cotrimoxazole-induced severe cutaneous adverse reactions (SCARs).
Abstract
The HLA-B*13:01 allele is a critical biomarker for dapsone- and cotrimoxazole-induced severe cutaneous adverse reactions (SCARs). Overcoming the limitations of centralized laboratory screening, we developed a portable electrochemical dual-sensing platform (EDP) for the simultaneous, ultrasensitive detection of HLA-B*13:01 alongside a TIMP-1 internal control. On screen-printed carbon electrodes (SPCEs), TIMP-1 is captured through robust biotin-streptavidin interactions, while HLA-B*13:01 relies on sequence-specific ssDNA hybridization. Crucially, the system utilizes methylene blue (MB) to precisely modulate both electrostatic repulsion and physical steric hindrance, enhancing signal discrimination. The platform demonstrates exceptional limits of detection, reaching 0.992 pg and 65.5 fg when evaluated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), respectively. Notably, accounting for genomic copy number, this corresponds to a practical detection limit of ∼3 HLA-B gene copies (1 × 10-2 ng genomic DNA), several orders of magnitude below conventional gel electrophoresis. Validated against 100 blinded clinical samples, the EDP achieved 100% sensitivity, specificity, and accuracy using ROC-derived cut-offs. By delivering a highly scalable, portable post-PCR screening tool, this work provides a high-performance alternative to standard methods, effectively mitigating SCAR risks and advancing the global accessibility of precision medicine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A cost-effective conventional endpoint PCR assay for HLA-B*13:01 genotyping to guide personalized dapsone therapy in leprosy in low-resource settings.Personalized medicine · 2026
- Dual-mode colorimetric sensing of bilirubin using a PDDA@peroxomolybdate composite: A spectrophotometric platform and cost-effective cotton-swab sensor for point-of-care testing.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Rapid electrochemical genosensing platform for direct detection of CTX-M-15 ESBL gene.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Intramolecular DNA Machine Coupled with Catalytic Redox-Recycling Amplification for Highly Efficient Electrochemical Detection of Dipicolinic AcidACS Sensors · 2026
- Disposable laser-induced graphene-based biosensor strip for the detection of N-protein using CRISPR activation and ratiometric electrochemical readoutTalanta · 2026
- Programmable Multisite Recognition Enables Amplification-Free Nanopore Detection of Mycobacterium tuberculosis in Sputum and Plasma.Nano letters · 2026