Analytical chemistry

Electrochemical Dual-Sensing Platform for HLA-B*13:01 Detection to Prevent Severe Cutaneous Adverse Reactions (SCARs) Induced by Dapsone and Cotrimoxazole.

Jirapat Attapong, Chollanot Kaset, Nontaya Nakkam, Wichittra Tassaneeyakul, Wichayaporn Kamsong, Chanpen Karuwan, Chonlaphat Sukasem, Sirinart Chomean

Department of Medical Technology, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani12120, Thailand. · Department of Pharmacology, Faculty of Medicine, Khon Kaen University, Khon Kaen40002, Thailand.

Key points

From the paper's conclusion
  • The HLA-B*13:01 allele is a critical biomarker for dapsone- and cotrimoxazole-induced severe cutaneous adverse reactions (SCARs).

Abstract

The HLA-B*13:01 allele is a critical biomarker for dapsone- and cotrimoxazole-induced severe cutaneous adverse reactions (SCARs). Overcoming the limitations of centralized laboratory screening, we developed a portable electrochemical dual-sensing platform (EDP) for the simultaneous, ultrasensitive detection of HLA-B*13:01 alongside a TIMP-1 internal control. On screen-printed carbon electrodes (SPCEs), TIMP-1 is captured through robust biotin-streptavidin interactions, while HLA-B*13:01 relies on sequence-specific ssDNA hybridization. Crucially, the system utilizes methylene blue (MB) to precisely modulate both electrostatic repulsion and physical steric hindrance, enhancing signal discrimination. The platform demonstrates exceptional limits of detection, reaching 0.992 pg and 65.5 fg when evaluated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), respectively. Notably, accounting for genomic copy number, this corresponds to a practical detection limit of ∼3 HLA-B gene copies (1 × 10-2 ng genomic DNA), several orders of magnitude below conventional gel electrophoresis. Validated against 100 blinded clinical samples, the EDP achieved 100% sensitivity, specificity, and accuracy using ROC-derived cut-offs. By delivering a highly scalable, portable post-PCR screening tool, this work provides a high-performance alternative to standard methods, effectively mitigating SCAR risks and advancing the global accessibility of precision medicine.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Electrochemical Dual-Sensing Platform for HLA-B*13:01 Detection to Prevent Severe Cutaneous Adverse Reactions (SCARs) Induced by Dapsone and Cotrimoxazole — Science Skim