Direct On-Bead 18O Labeling Coupled with SP3 Sample Preparation (SP-18O) and DIA-MS for Quantitative Proteomics.
Shakhzodjon Uzokboev, Yi-Kai Liu, Zheng Zhang, Lucas Kramer, Meng-Ju Wu, Vikki M Weake, W Andy Tao
Department of Chemistry, Purdue University, West Lafayette, Indiana47907, United States. · Department of Biochemistry, Purdue University, West Lafayette, Indiana47907, United States.
Key points
From the paper's conclusion- Here, we present a fully integrated platform combining single-pot solid-phase-enhanced sample preparation (SP3) with direct on-bead trypsin-catalyzed C-terminal 18O labeling (SP-18O) during proteolytic digestion and data-independent acquisition mass spectrometry (DIA-MS).
Abstract
Quantitative proteomics requires robust, accurate labeling strategies that minimize sample handling and preserve analytical sensitivity. Enzymatic 18O labeling offers a simple, universally applicable alternative to other isotopic labeling methods, but has been limited by incomplete labeling, back-exchange, and reliance on post-digestion, in-solution 18O labeling workflows that are impractical and introduce cumulative sample losses. Here, we present a fully integrated platform combining single-pot solid-phase-enhanced sample preparation (SP3) with direct on-bead trypsin-catalyzed C-terminal 18O labeling (SP-18O) during proteolytic digestion and data-independent acquisition mass spectrometry (DIA-MS). By performing 18O incorporation directly on-bead during digestion, the SP-18O approach eliminates the need for a separate post-digestion labeling step and associated sample losses compared to conventional enzymatic labeling workflows. Integration with DIA-MS further improves identification confidence and quantitative performance through distinctive y-ions. The platform is validated on two biologically distinct sample types, extracellular vesicles (EVs) secreted from model cancer cells and immunoaffinity-enriched protein complexes from Drosophila head tissue, demonstrating robustness and generalizability. This integrated strategy offers a practical, cost-effective solution for accurate quantitative proteomics while minimizing sample loss and analysis time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Robust Strategy for High-Throughput and Deep Proteomics by Combining Narrow-Window Data-Independent Acquisition and Isobaric Mass TaggingJournal of Proteome Research · 2025
- Optimizing Spectral Reference Library Generation Strategies for Data-Independent Acquisition Proteomics in Clinical Cancer CohortsJournal of Proteome Research · 2026
- BrIS: Visualizing Internal Standards at the MS1 Level via Bromine Fingerprint for Sensitive and Robust Proteomics Quality Control.Angewandte Chemie (International ed. in English) · 2026
- Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) for Quantitative Proteomics.Advances in experimental medicine and biology · 2026
- ProjDIA: Fragment-Bin Projection Scoring and Calibrated Confidence for Direct Infusion DIA Proteomics.ACS measurement science au · 2026
- Reference-Anchored Scale Alignment Enables Cross-platform Harmonization of Protein Concentrations in Label-Free Plasma ProteomicsAnalytical Chemistry · 2026