Reference-Anchored Scale Alignment Enables Cross-platform Harmonization of Protein Concentrations in Label-Free Plasma Proteomics
André Q. Figueiredo, Inês F. Domingos, Luís B. Carvalho, Jacek R. Wiśniewski, Rajiv Dhir, Carlos Lodeiro, José L. Capelo, Dimitrios Korentzelos,
Key points
From the paper's conclusion- Here we introduce reference-anchored absolute proteomics (RAAP), a post-acquisition scale-alignment strategy that maps TPA-derived concentrations onto a physiologically interpretable scale through multiplicative anchoring to stable endogenous plasma proteins.
Abstract
Accurate, reproducible protein quantification across diverse mass spectrometry platforms remains a critical bottleneck in biomarker discovery. Label-free methods such as the total protein approach (TPA) achieve scalability without external standards but exhibit substantial cross-platform variability, while stable isotope-labelled standards cannot scale to proteome-wide datasets. Here we introduce reference-anchored absolute proteomics (RAAP), a post-acquisition scale-alignment strategy that maps TPA-derived concentrations onto a physiologically interpretable scale through multiplicative anchoring to stable endogenous plasma proteins. Evaluated across 330 LC−MS/MS runs from 22 analytical configurations implemented across 8 laboratories, RAAP showed strong anchor dependence: SERPINA1 and transferrin reduced the upper 95% limits of agreement from 3.7-fold to 2.8-fold and 3.4-fold respectively, whereas albumin introduced bias and increased the upper agreement bound. In runs with reduced proteome coverage, TF-RAAP increased reference-interval concordance among non-anchor proteins from 18.8% to 33.3%, although this improvement was not statistically significant (p = 0.070). Analysis of the fibrinogen complex demonstrated preservation of inter-chain molar ratios following RAAP scale alignment, consistent with uniform proportional scaling. These results show that endogenous reference-protein anchoring provides a practical post-acquisition strategy for harmonizing label-free proteomic concentration scales across heterogeneous LC−MS platforms. SERPINA1-based alignment reduced the upper agreement bound by approximately 24% relative to baseline TPA while expressing results on a physiologically interpretable concentration scale, supporting more consistent quantitative comparisons across analytical platforms and laboratories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Plasma titration provides a physical ruler for cross-platform proteomicsbioRxiv · 2026
- Rank-Preserving Alignment Enables Cross-platform Learning and Phenotyping for Single-Cell and Spatial ProteomicsbioRxiv · 2026
- Multicenter evaluation of label-free quantification in human plasma on a high dynamic range benchmark setNature Communications · 2025
- Machine learning cross-platform proteomic imputation enables protein quality scoring and replication of epidemiological associationsbioRxiv · 2026
- A draft atlas of the human plasma proteome at isoform resolutionbioRxiv · 2026
- Comparative evaluation of Olink Explore 3072 and mass spectrometry with peptide fractionation for plasma proteomicsCommunications Chemistry · 2025