A Pretreatment Workflow for Cadmium Isotope Analysis of Ultra-Trace Samples Using Large-Mass Digestion and Stepwise Purification.
Yu Cheng, Guangyi Sun, Weihai Yu, Xian Wu, Zeming Shi, Xinbin Feng
State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang550081, China. · Chengdu University of Technology , Chengdu610059, China.
Key points
From the paper's conclusion- Overall, this workflow provides a reliable and scalable pretreatment approach for gram-scale, low-Cd, matrix-rich samples, extending Cd isotope analysis to materials with Cd concentrations down to approximately 5 ng g−1.
Abstract
Cadmium (Cd) occurs at ultra-trace levels in geological and environmental materials, and conventional digestion procedures often fail to provide sufficient Cd for high-precision isotopic analysis. Increasing the sample mass can alleviate this limitation; however, it introduces substantial matrix loads that complicate subsequent purification. Here, we develop an integrated pretreatment workflow for low-Cd, matrix-rich solid samples by combining large-mass digestion (up to 5 g), batch resin-based prepurification, and final column purification. This approach enables efficient Cd isolation and quantitative recovery under matrix-rich conditions while maintaining low total procedural blanks (0.04-0.10 ng). In this workflow, the AG-MP-1M resin is applied in a batch resin-based prepurification step prior to column purification to effectively remove major matrix elements. For the soil reference material GSS-3a, the Cd recoveries exceeded 95% across digestion masses of 0.5-5 g, whereas the δ114/110Cd values remained highly consistent (-0.373 ± 0.054‰, 2 SD, n = 14), indicating that no resolvable isotope bias was introduced with the increasing sample load. Binary mixing experiments between GSS-3a and NIST SRM 2711a show excellent agreement with the theoretical predictions (R2 = 0.9933). Further validation using soils derived from different parent materials and a suite of reference materials (soils, sediments, rocks, and plants) demonstrated the robustness and matrix tolerance of the workflow. Overall, this workflow provides a reliable and scalable pretreatment approach for gram-scale, low-Cd, matrix-rich samples, extending Cd isotope analysis to materials with Cd concentrations down to approximately 5 ng g-1.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- One‐Column Pre‐Separation of Si, Fe, Mg and Ca from Reference Materials for Isotope MeasurementsGeostandards and Geoanalytical Research · 2026
- Cadmium Stable Isotopes in Environmental Source Tracing and Cross-Media Transport.Toxics · 2026
- Overcoming Ru-99 Isobaric Overlap via C2H4 as a Reaction Gas for Tc-99 Accurate Measurement in Large-Volume Seawater Samples by Triple Quadrupole ICP−MS with Mass-Shift ModeAnalytical Chemistry · 2026
- Synthetic Cassiterite Reference Material for High-Precision In Situ Sn Isotope Analysis by LA-MC-ICP-MS.Analytical chemistry · 2026
- Combined LA-ICP-MS with empirical coefficient correction and Bi fire assay for the determination of ultra-trace Pt, Pd, and Au in geochemical samples using a 194Pt isotope spike as the internal standard.Analytical methods : advancing methods and applications · 2026
- Rapid determination of Ru, Rh, Pd, Ir, and Pt in rock samples using ICP-MS following microwave digestion.Talanta · 2026