Molecularly Imprinted Photoelectrochemical Sensor Designed by Molecular Dynamics Simulation Calculations for Highly Selective and Ultrasensitive Detection of Illicit Drugs
Hao Li, Ruiying Zhang, Yuting Kui, Yiting Wang, Yuwei Zhao, Xiaosi Sang, Jingli Shen, Yuhang Zhang,
Yunnan University · South China University of Technology
Key points
From the paper's conclusion- Herein, the molecular dynamics (MD) simulation calculation-based molecularly imprinted polymer (MIP) with excellent recognition capability and the ZnO-CuO p-n heterojunction with efficient charge separation were prepared to fabricate a novel molecularly imprinted photoelectrochemical (MIP-PEC) sensor for the specific and ultrasensitive detection of KT.
Abstract
As one of the most prevalent drugs, ketamine (KT) presents a significant social risk, making the development of a specific and ultrasensitive detection tool essential. Herein, the molecular dynamics (MD) simulation calculation-based molecularly imprinted polymer (MIP) with excellent recognition capability and the ZnO-CuO p-n heterojunction with efficient charge separation were prepared to fabricate a novel molecularly imprinted photoelectrochemical (MIP-PEC) sensor for the specific and ultrasensitive detection of KT. Impressively, compared with traditional MIP preparation methods that suffer from limited selectivity and inefficient trial-and-error component screening, MD simulation calculations enable the rational design of highly selective MIP, reducing costs and enhancing efficiency. Specifically, the binding energy of KT with functional monomers and cross-linkers, along with the solvation energy of solvents, were analyzed by MD simulation calculations, ultimately identifying the methacrylic acid (MAA), ethylene glycol dimethacrylate (EGDMA), and acetonitrile (ACN) as the optimal components to build MIP with precisely recognized cavities, which effectively improved the detection selectivity of the designed sensor. Furthermore, the ZnO-CuO p-n heterojunction with a precisely matched band effectively reduced the recombination rate of carriers, enhancing photoelectric response and stability. As a result, the constructed MIP-PEC sensor successfully achieved a specific and ultrasensitive assay of KT with a low detection limit down to 0.746 nM, an imprinting factor (IF) of 8.75, and a selectivity factor (SF) of 4.70, surpassing previous reports and enabling successful application in urine, saliva, and wastewater samples. This study provides a distinctly specific and ultrasensitive analytical platform for the assay of illegal drugs in the field of social security.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl DetectionAnalytical Chemistry · 2026
- Rapid carbamazepine detection by means of a disposable electrochemical sensor based on a molecularly imprinted polymerTalanta · 2025
- A Synergistic Experimental and Computational Approach to the Design of MIPs Targeting Metronidazole.Analytical chemistry · 2026
- From Lab to Body: Advanced Electrochemical Biosensors for Illicit Drug Detection via Nanomaterials, AI, and Wearable TechACS Sensors · 2025
- Dual-sensor potentiometric platform utilizing β-cyclodextrin ionophores and Cu-gallic MOFs for ophthalmic drugs determination in rabbit aqueous humorSensing and Bio-Sensing Research · 2026
- Molecular Imprinting Polymer (MIP)-Based Technologies and Applications for the Detection and Identification of Psychoactive SubstancesAnalytica · 2026