Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection
Arati Biswakarma, Wujian Miao
University of Southern Mississippi
Key points
From the paper's conclusion- Under optimized conditions, the MIP-ECL sensor exhibited a limit of detection of ∼1 μM (S/N = 3), equivalent to 3.4 ng of fentanyl using 10 μL solution, with three distinctive linear regions spanning 1.0 to 6.0, 6.0 to 40.0, and 40.0 to 70.0 μM.
Abstract
High Resolution Image Download MS PowerPoint Slide The escalating prevalence of fentanyl, a highly potent synthetic opioid responsible for rising overdose fatalities and public health crises, underscores the critical need for sensitive and selective detection methodologies. Herein, we report a molecularly imprinted polymer (MIP)-based electrogenerated chemiluminescence (ECL) sensor for ultrasensitive and selective quantification of fentanyl. The sensor was fabricated by electropolymerizing 4-aminobenzoic acid (4-ABA) on a glassy carbon electrode (GCE) in the presence of fentanyl as the template, followed by template elution to yield recognition nanocavities within the MIP film. ECL signal transduction was achieved through the anodic coreactant pathway, wherein fentanyl (as the coreactant) bound within the MIP cavities reacted with solution-phase [Ru(bpy) 3 ] 2+ (as the ECL emitter) in phosphate buffer (pH 7.5) during anodic scans from 0 to 1.60 V vs Ag/AgCl (3.0 M KCl). Critical fabrication and operational parameters, including electropolymerization cycles, template concentration and molar ratio to the monomer, elution conditions, and rebinding duration, were systematically optimized. Density functional theory and density of states investigations guided elution solvent selection and elucidated favorable fentanyl–polymer interactions, verifying the sensor’s specificity toward fentanyl over five common structurally similar interferents. Under optimized conditions, the MIP-ECL sensor exhibited a limit of detection of ∼1 μM (S/N = 3), equivalent to 3.4 ng of fentanyl using 10 μL solution, with three distinctive linear regions spanning 1.0 to 6.0, 6.0 to 40.0, and 40.0 to 70.0 μM. Additionally, the sensor demonstrated high reproducibility and stability, positioning it as a promising platform for rapid forensic analysis of illicit fentanyl.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Direct ECL Detection of Fentanyl Drug with Bare Screen-Printed ElectrodesBiosensors · 2025
- Molecularly Imprinted Photoelectrochemical Sensor Designed by Molecular Dynamics Simulation Calculations for Highly Selective and Ultrasensitive Detection of Illicit DrugsAnalytical Chemistry · 2026
- Rapid carbamazepine detection by means of a disposable electrochemical sensor based on a molecularly imprinted polymerTalanta · 2025
- Next-generation electrochemical sensors for opioid detection: from nanostructured interfaces towards real-time clinical monitoring.Analytical methods : advancing methods and applications · 2026
- Electrochemical detection of fluoxetine using a carbon cloth–supported ZrO2/molecularly imprinted polymer designed by DFTJournal of Science Advanced Materials and Devices · 2026
- Femtomolar Congener-Selective Detection of Perfluoroalkyl Substances in Water by a Cyclodextrin-Oriented Molecularly Imprinted Transistor SensorEnvironmental Science & Technology · 2026