Toward Accurate Estimation of Extractable Organic Fluorine by Analysis of Fluoride Contamination in Extracts Using Gas Chromatography
Johannes Kikuchi, Malin Montelius, Gustav Sporre, David Bastviken, Teresia Svensson
Linköping University · Swedish Geotechnical Institute
Key points
From the paper's conclusion- Therefore, the analysis and discount of F – in EOF extracts are essential for accurate EOF determination by CIC.
Abstract
High Resolution Image Download MS PowerPoint Slide Extractable organic fluorine (EOF) analysis is used to assess fluorinated organic content in, e.g., water and solid sample extracts. EOF content is often determined by combustion ion chromatography (CIC). However, contamination from inorganic fluoride (F – ) in extracts risks overestimating actual EOF. Despite this known interference, a standardized and optimized methodology to mitigate such contamination remains lacking. In this study, we evaluated the presence of F – in EOF extracts and designed and validated a method for F – determination in small aliquots (∼250 μL) of complex aqueous and solvent matrices. The method is based on derivatization of F – to triphenylfluorosilane (TPSiF) and subsequent analysis with gas-chromatographic tandem mass spectrometry analysis (GC–MS/MS). Calibration was linear from 1 to 1000 μg L –1 ( R 2 > 0.99), and the limit of detection and the limit of quantification were 0.98 and 4.5 μg F – L –1, respectively. The relative standard deviation was below 7% across the calibrated range. A certified reference material (CRM River water) and F – -spiked minced meat were used to assess F – recovery to 103 ± 3% ( p = 0.10) and 95 ± 6% ( p = 0.31) of certified/spiked concentrations. Analysis of sample extracts showed that (1) solid-phase extraction extracts of river water, (2) solvent extracts from aqueous-film-forming foam (AFFF)-impacted soil, and (3) extracts of a fish sample contained 29–49, 61 ± 4.7, and 17–90 μg F – L –1, respectively. F – accounted for 3–59% of the measured EOF, indicating a substantial overestimation. Therefore, the analysis and discount of F – in EOF extracts are essential for accurate EOF determination by CIC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Capturing the Organic Fluorine in Aqueous Film-Forming Foam (AFFF)-Impacted Groundwater: Suspect Screening, Extractable Organofluorine, and the Total Oxidizable Precursor Assay.Environmental science & technology · 2026
- Advancing Total Fluorine Measurement of PFAS in Liquid Samples Using HR-CS-GFMASACS ES&T Water · 2026
- The hidden fluorine: a critical review of analytical methods for unmasking PFAS and closing fluorine mass balance in environmental samplesAnalytical and Bioanalytical Chemistry · 2026
- Trifluoroacetic Acid (TFA) Exceeds All Other Extractable Organofluorine in Drinking Water from Eastern Massachusetts, United States.Environmental science & technology letters · 2026
- Automatic Online Combustion‐Ion Chromatography for High‐Precision Determination of Fluorine and Chlorine in Trace SamplesGeostandards and Geoanalytical Research · 2026
- Identification of Novel PFAS Transformation Products in AFFF-Impacted Surface and Groundwater.Environmental science & technology · 2026