Aptamer-Gated Organic Photoelectrochemical Transistor Biosensor Based on a TiO₂ -Embedded Vertically Ordered Mesoporous SiO₂ Film for Sensitive Detection of Carcinoembryonic Antigen
Xuran Tian, Linyue Tang, Yulan Zeng, Zhonghui Chen, Bin Qiu, Zhenyu Lin, Huixing Chen
Fuzhou University · Putian University
Key points
From the paper's conclusion- This study developed an organic photoelectrochemical transistor (OPECT) biosensor based on TiO 2 -embedded vertically ordered mesoporous silica film (VMSF) modified ITO electrode for ultrasensitive detection of carcinoembryonic antigen (CEA).
Abstract
This study developed an organic photoelectrochemical transistor (OPECT) biosensor based on TiO 2 -embedded vertically ordered mesoporous silica film (VMSF) modified ITO electrode for ultrasensitive detection of carcinoembryonic antigen (CEA). The sensor uses VMSF as a molecular gate, with the complementary DNA (cDNA) of the CEA aptamer immobilized at the entrances of the mesoporous channels for specific target recognition. In the absence of CEA, cDNA and the aptamer form stable double-stranded DNA (dsDNA), blocking Ru(phen) 3 2+ from entering the channels and suppressing the photoelectrochemical signal. When CEA is present, it triggers the release of cDNA, which is cleaved by exonuclease I (Exo I), opening the molecular gate and enhancing the photocurrent signal. The Exo I-assisted signal amplification strategy significantly improves the sensor’s sensitivity. Additionally, TiO 2 nanoparticles are embedded in the VMSF channels, combining TiO 2 ’s photoelectrochemical properties with VMSF’s molecular sieving function, optimizing charge separation and migration efficiency, and enhancing the photoelectrochemical signal. The energy level alignment between TiO 2 and Ru(phen) 3 2+ promotes photoelectric conversion efficiency, while the negative charge on VMSF improves antifouling ability and selectivity. Furthermore, the positively charged Ru(phen) 3 2+ can enters and accumulated in the mesopores of negatively charged VMSF through electrostatic interactions, thereby enhancing the detected signal output under light irradiation. The sensor has a detection range of 100 fg/mL to 500 ng/mL and a minimum detection limit of 0.031 pg/mL, significantly outperforming conventional sensors, demonstrating broad clinical application potential.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Oxygen vacancies-induced dual-interface modulation for TiO2/BiOI-based photoelectrochemical biosensor of urinary cancer markers.Biosensors & bioelectronics · 2026
- In Situ Ion-Exchange-Mediated Dynamic Nanointerface Reconfiguration for Polarity-Switchable Photoelectrochemical-Photothermal Biosensing.Journal of the American Chemical Society · 2026
- Self-Powered Organic Photoelectrochemical Transistor DetectionAnalytical Chemistry · 2026
- Ce/Zr-MOF- and TCEP-Mediated Ascorbic Acid Generation for In Situ Oxygen Vacancy Regulation in Bi4O5I2/Bi2S3 Gate: A Triple-Mode Biosensor for ALKBH5 Detection.Analytical chemistry · 2026
- Enzyme-Induced Photocurrent Polarity Reversal in a Zr-MOF/COF Photoelectrochemical Immunosensor for Ultrasensitive Detection of Cancer Markers.Langmuir : the ACS journal of surfaces and colloids · 2026
- Dual Amplification on Coordination-Engineered Photogate for Sensitive Organic Photoelectrochemical Transistor Biosensing.Analytical chemistry · 2026