Testing a Minimal Three-Zone Surgical Setup Under Infrastructure-Degraded Conditions.
Peter Dorzweiler, Katharina Schötz, Manuel Döhla
University of Bonn, University Hospital Bonn, Institute for Hygiene and Public Health, Bonn, Germany. · Department of Preventive and Veterinary Medicine; Bundeswehr Healthcare Command, Koblenz, Germany.
Key points
From the paper's conclusion- We operationally evaluated a minimal 3-zone surgical setup consisting of a contaminated dirty zone (12 m2), a semiclean transition zone (15 m2), and a protected procedural core (14 m2).
Abstract
Infrastructure degradation during conflicts and disasters may necessitate temporary surgical capability in improvised environments lacking conventional operating-room infrastructure. We operationally evaluated a minimal 3-zone surgical setup consisting of a contaminated dirty zone (12 m2), a semiclean transition zone (15 m2), and a protected procedural core (14 m2). Workflow simulations demonstrated reproducible separation of patient, personnel, material, and waste flows within a total operational footprint of 41 m2. Spatial demand was primarily determined by contamination control, workflow separation, and procedural movement geometry.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond the Room: Bed-Level Isolation as Surge-Capable Infrastructure for Pandemics and Disasters-A Conceptual Framework.Disaster medicine and public health preparedness · 2026
- Protective accessibility for resilient urban mobility under recurrent air threatsDiscover Cities · 2026
- Medical device availability under system degradation: a dependency-based framework for adaptive responses and risk-informed decision-making.GMS hygiene and infection control · 2026
- Anästhesiologie als integrative Querschnittsdisziplin der klinischen Resilienz – Was Kliniken jetzt für den Hochlastbetrieb vordenken müssenDie Anaesthesiologie · 2026
- Surgery Is Not a Place: Time-to-Scalpel, Surgical Throughput, and Dynamic Load Balancing in Large-Scale Combat Operations.Military medicine · 2026
- METHODOLOGICAL LIMITATIONS OF NORMATIVE DESIGN OF PHYSICAL PROTECTION SYSTEMS FOR CRITICAL AND MILITARY FACILITIES IN A DYNAMIC THREAT ENVIRONMENTГРААЛЬ НАУКИ · 2026