Performance Evaluation of Spanish Biological Dosimetry Laboratories Through Interlaboratory Comparisons
Anna Francès-Abellán, Alegria Montoro, Julien Alcaide, Miguel Alcaraz, Gemma Armengol, Inmaculada Domínguez, José Luis Fernández García, Celia Fernández Martín,
Key points
From the paper's conclusion- Objective This study reports two interlaboratory comparisons (ILCs) dedicated to harmonizing biological dosimetry laboratories in Spain.
Abstract
Objective This study reports two interlaboratory comparisons (ILCs) dedicated to harmonizing biological dosimetry laboratories in Spain. Methods Two established techniques were applied among six laboratories: the dicentric chromosome assay (DCA) and the cytokinesis-block micronucleus (CBMN) assay. In the first ILC, blood samples were irradiated ex vivo at 2.9 Gy and 1.4 Gy. In the second ILC, a 2.63 Gy exposure was delivered generating a whole-body sample and a partial-body sample. Results In triage conditions using DCA, scoring 20 cells was sufficient to accurately classify doses above 2 Gy (i.e., high exposure) for rapid clinical prioritization, and 50 cells generally provided reliable estimates inside the ± $ \pm $ plus or minus 0.5 Gy acceptance limit. The laboratories which could evaluate 500 cells obtained results where the 95% confidence intervals included the delivered dose. For partial-body exposures, scoring more than 50 cells was required at the tested dose (2.63 Gy) to ensure reliable DCA estimates. The CBMN assay successfully assessed whole-body exposure in the second exercise but could not identify partial-body exposure. Conclusions These ILCs demonstrate a general consistency among participant laboratories for whole-body dose assessment using both DCA and CBMN. However, further optimization is required for reliable application in partial-body triage scenarios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of a deep neural network workflow for fully automated dicentric chromosome analysis in biological dosimetryScientific Reports · 2026
- Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.Mutation research. Genetic toxicology and environmental mutagenesis · 2026
- Artificial intelligence-driven advancements in radiation biodosimetry.Mutation research. Genetic toxicology and environmental mutagenesis · 2026
- Perspectives of IABERD on biodosimetry strategies for a large-scale nuclear eventInternational Journal of Radiation Biology · 2025
- DCA-based dose estimation methodologies for criticality accidents.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- From whole-body dosimetry to local dose assessment: a 3-y experience in interventional practice.Radiation protection dosimetry · 2026