Mitigating conduction disturbances in sutureless aortic valve surgery: A standardized anti-oversizing strategy in a large single-center program.
Miguel Barbeito González, Gabriel González Barbeito, María García Vieites, Carlos Velasco García de Sierra, Víctor Xesus Mosquera Rodríguez, Francisco Estévez Cid, José Martínez Comendador, José J Cuenca Castillo
Department of Cardiac Surgery, Structural and Congenital Heart Disease Research Group, Instituto de Investigación Biomédica de A Coruña (INIBIC), Complexo Hospitalario Universitario de A Coruña (CHUAC), Sergas/Universidade da Coruña (UDC), A Coruña, Spain. · Department of Cardiology, University Hospital of A Coruña, A Coruña, Spain.
Key points
From the paper's conclusion- In a large real-world sutureless aortic valve program, standardization of sizing and implant depth was associated with sustained reduction in permanent pacemaker implantation without compromising clinical outcomes. Avoidance of oversizing appears central to optimizing conduction results.
Abstract
OBJECTIVES: The study objectives were to characterize conduction outcomes and perioperative results in a large, consecutive, single-center program of sutureless self-expanding aortic bioprosthesis implantation and to assess the temporal impact of a standardized, nonoversizing, higher-release implant strategy on permanent pacemaker implantation. METHODS: We conducted a retrospective cohort study including all sutureless aortic valve procedures performed between October 2013 and March 2025 (n = 1742). Outcomes assessed were permanent pacemaker implantation for complete atrioventricular block, stroke, reexploration for bleeding, renal replacement therapy, infection, and in-hospital mortality. Prespecified subgroup analyses were performed for isolated aortic valve surgery and by surgical approach (full sternotomy vs ministernotomy). Temporal trends were examined across the program's learning curve, with 2017 marking the adoption of a standardized conservative depth, no oversizing implantation strategy. Body size index-prosthesis size interactions were explored using heat-map analyses. RESULTS: Overall permanent pacemaker implantation occurred in 96 of 1742 patients (5.5%). Rates of stroke, reexploration for bleeding, renal replacement therapy, and in-hospital mortality were 1.7%, 4.7%, 1.8%, and 3.4%, respectively. In isolated surgery (n = 1281), ministernotomy was associated with lower stroke (0.95% vs 3.30%; P = .003), lower renal replacement therapy (0.63% vs 3.00%; P = .001), and lower in-hospital mortality (1.69% vs 6.31%; P < .001) compared with full sternotomy, and permanent pacemaker implantation rates were similar (5.27% vs 5.11%; P = .908). Cumulative permanent pacemaker implantation incidence decreased from early values of approximately 12 to 14% to 5 to 6% after 2017, paralleling adoption of the standardized implantation strategy. Heat-map analyses demonstrated pre-2017 oversizing "hot spots" that largely resolved after standardization. CONCLUSIONS: In a large real-world sutureless aortic valve program, standardization of sizing and implant depth was associated with sustained reduction in permanent pacemaker implantation without compromising clinical outcomes. Avoidance of oversizing appears central to optimizing conduction results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Permanent pacemaker implantation after sutureless aortic valve replacement with the perceval valve: predictors and clinical implications.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Long-term clinical and hemodynamic outcomes of the Perceval aortic sutureless bioprosthesisEuropean Heart Journal · 2026
- Long-term outcomes of surgical aortic valve replacement using a third-generation stented bovine pericardial bioprosthesis in 1907 patients.JTCVS open · 2026
- The Cusp-Overlap Technique Versus the Standard Three-Cusp Technique for Self-Expanding Transcatheter Aortic Valves-A Single-Center Experience.Journal of clinical medicine · 2026
- A 14-year Single-center Experience With the Solo Valve.CJC open · 2026
- Mechanical vs. sutureless aortic valve replacement: clinical outcomes and the contribution of preoperative multislice CTCardiovascular journal of South Africa/Cardiovascular journal of Southern Africa · 2026