Indications for and characteristics of redo aortic valve replacement after primary mechanical aortic valve replacement.
Harrison R Herrera, Hartzell V Schaff, Rolando Calderon-Rojas, Kevin L Greason, Joseph A Dearani, Malakh L Shrestha, Richard C Daly, Austin Todd,
Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minn. · Department of Quantitative Health Sciences, Mayo Clinic, Rochester, Minn.
Key points
From the paper's conclusion- Redo AVR after previous mechanical AVR is uncommon and arises from heterogeneous indications. Early risk is greatest with endocarditis and nonelective presentation, whereas long-term survival is driven largely by comorbidities rather than indication or prosthesis type. These findings may guide risk assessment, prosthesis selection, and timing of intervention.
Abstract
OBJECTIVE: To define the indications and characteristics for redo aortic valve replacement (AVR) after primary mechanical AVR and to determine whether operative indication influences early and late outcomes. METHODS: We analyzed 379 consecutive patients undergoing redo AVR after previous mechanical AVR (2000-2023) at a single tertiary center. Baseline, operative, and outcomes data were obtained from a prospectively maintained database and electronic health records. Outcomes were compared across principal indications, with survival estimated by Kaplan-Meier analysis and predictors of mortality identified using multivariable Cox regression. RESULTS: Median age at redo surgery was 61.8 years (interquartile range, 52.4-69.4 years); 61.2% were male. The median interval to reoperation was 10.2 years (3.9-18.2). Indications included endocarditis (26.6%), pannus obstruction (18.7%), prosthesis-patient mismatch (11.6%), and elective replacement during aortic surgery (16.0%). Endocarditis cases were frequently nonelective and had longer operative times, greater complication rates, and greater operative mortality (13.0% vs 1.4% pannus and 3.4% others; P < .001). Independent predictors of all-cause mortality were older age, diabetes, dialysis dependence, previous myocardial infarction, and nonelective surgery. Indication, including endocarditis, and valve size were not independent predictors. Lower overall survival in endocarditis and bioprosthetic redo cases reflected excess early mortality; beyond 1 year, survival was similar across indications. CONCLUSIONS: Redo AVR after previous mechanical AVR is uncommon and arises from heterogeneous indications. Early risk is greatest with endocarditis and nonelective presentation, whereas long-term survival is driven largely by comorbidities rather than indication or prosthesis type. These findings may guide risk assessment, prosthesis selection, and timing of intervention.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term outcomes and benchmarks of redo surgical aortic valve replacement in Japanese patients: insights from a multicenter registry.General thoracic and cardiovascular surgery · 2026
- Early Mortality in Reoperative Cardiac Surgery: Determinants, Prediction, and Calibration.Diagnostics (Basel, Switzerland) · 2026
- Transcatheter Valve-in-Valve versus Surgical Aortic Valve Replacement for Failed Bioprostheses: AI-ECG Age as a Marker of Mortality.The Journal of thoracic and cardiovascular surgery · 2026
- The Ross Procedure After Previous Aortic Valve Surgery: Propensity-Weighted Comparison of Mid-Term Outcomes.The Journal of thoracic and cardiovascular surgery · 2026
- Impact of valve position and prosthesis type on outcomes of valve replacement in end-stage renal disease patients with infective endocarditis.JTCVS open · 2026
- The Price of Redo Mitral Valve Replacement: Determinants of Major Adverse Postoperative Events.Journal of cardiovascular development and disease · 2026