Impact of valve position and prosthesis type on outcomes of valve replacement in end-stage renal disease patients with infective endocarditis.
Berk Inan, Marco Tagliafierro, Ian Mason, Darina Kirilina, Christine Yang, James Lao, Gerardo Ramos-Lemos, Sumit Mohan,
Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ. · Division of Cardiac Surgery, Columbia University Irving Medical Center, New York, NY.
Key points
From the paper's conclusion- Mortality for end-stage renal disease patients undergoing valve replacement for infective endocarditis is high, with outcomes varying by valve position. Prosthesis type did not consistently affect survival, reinfection, or stroke. These findings highlight the limited impact of prosthesis type and emphasize the importance of broader perioperative and systemic management strategies.
Abstract
OBJECTIVE: End-stage renal disease patients with infective endocarditis face high operative risk and poor survival. We sought to compare outcomes of mechanical versus bioprosthetic valve replacement in end-stage renal disease infective endocarditis, stratified by valve position. METHODS: Consecutive end-stage renal disease patients with acute infective endocarditis (2015-2020) in the US Renal Data System who underwent valve replacement were included and stratified by valve position and prosthesis type. Outcomes included mortality, reinfection, reoperation, and stroke. Mortality, reinfection, and stroke were assessed with cumulative incidence functions using transplant and death as competing risks, respectively. Inverse probability of treatment weighting was used for covariate balance, and cubic splines modeled age-prosthesis interactions. RESULTS: Of 1562 patients, 595 underwent aortic valve replacement, 685 underwent mitral valve replacement, 238 underwent aortic valve replacement + mitral valve replacement, and 44 underwent tricuspid valve replacement. Bioprosthetic valves were used in 73.4%. Operative mortality was 14.5% overall, lowest in aortic valve replacement (10.8%) and highest in aortic valve replacement + mitral valve replacement (23.5%; P < .001). Five-year mortality was 73.5% for mechanical and 76.0% for bioprosthetic valves, with no significant differences by valve type within any position. Reinfection occurred in 17.6% and did not differ by prosthesis. Reoperation was uncommon but higher in bioprosthetic mitral valve replacement (P = .023). Stroke was infrequent and did not significantly differ between valve types across any position. CONCLUSIONS: Mortality for end-stage renal disease patients undergoing valve replacement for infective endocarditis is high, with outcomes varying by valve position. Prosthesis type did not consistently affect survival, reinfection, or stroke. These findings highlight the limited impact of prosthesis type and emphasize the importance of broader perioperative and systemic management strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prosthetic valve endocarditis: valve type, microbiological patterns, and mortality-a nationwide multicenter cohort study.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2026
- Nationwide 5-year outcomes in U.S. dialysis patients with failed bioprosthetic surgical AVR: valve-in-valve TAVR versus redo surgeryEuropean Heart Journal · 2026
- Infective endocarditis after transcatheter versus surgical pulmonary valve replacement in CHD: absolute risk translation and device-material context.Cardiology in the young · 2026
- Mechanical versus bioprosthetic valves in aortic root replacement for acute type A dissection.Cardiovascular revascularization medicine : including molecular interventions · 2026
- Mechanical versus bioprosthetic aortic valves: the ultimate trade-offs every middle-aged patient should know.Journal of cardiothoracic surgery · 2026
- Indications for and characteristics of redo aortic valve replacement after primary mechanical aortic valve replacement.JTCVS open · 2026