World neurosurgery

Longitudinal boundary-anchored CT profiling of the frontal horns after cerebrospinal fluid shunting in idiopathic intracranial hypertension: a pilot study.

Malvina Garner, Frederik Fries, Christoph Garner, Alena Haußmann, Wolfgang Reith, Umut Yilmaz

Department of Neuroradiology, Saarland University Hospital, Kirrberger Str. D-66424 Homburg/Saar, Germany. · Department of Neuroradiology, Saarland University Hospital, Kirrberger Str. D-66424 Homburg/Saar, Germany. Electronic address: umut.yilmaz@uks.eu.

Observational · n=18

Key points

From the paper's conclusion
  • Boundary-anchored CT profiling identified postoperative frontal horn profile-shape changes supported by multiplicity-adjusted and sampling sensitivity analyses. Reproducibility was marker dependent, with repeatability limits exceeding mean early changes. These findings support further evaluation of the method as a quantitative research tool, with standardization and external validation required before clinical use.

Abstract

BACKGROUND: Routine CT after cerebrospinal fluid shunting in idiopathic intracranial hypertension (IIH) is usually assessed for catheter position and overt complications. We investigated whether boundary-anchored line profiling can detect subtler postoperative changes at the frontal horns. METHODS: This retrospective single-center study included 18 patients with IIH and 3 cranial CT examinations: baseline (T0), postoperative (T1), and follow-up (T2). Primary markers were local plateau dip depth, dip area, and biphasic index. Wilcoxon tests were adjusted for multiple comparisons. Additional analyses assessed clinical records, ventricular dimensions, baseline timing, scanner groups, and 2-mm sampling. Intra- and inter-rater reproducibility was assessed across all 54 examinations. RESULTS: Local plateau dip depth decreased from T0 to T1 and remained lower at T2; dip area and biphasic index decreased from T0 to T1 (all four q = 0.025). All three T0-to-T1 changes remained significant in the 2-mm sampling sensitivity analysis (q = 0.007-0.039). Conventional attenuation summaries and ventricular dimensions showed no significant longitudinal changes. Intra-/inter-rater intraclass correlation coefficients were 0.75/0.61 for dip depth, 0.73/0.49 for dip area, and 0.82/0.80 for biphasic index. Exploratory clinical associations did not survive multiplicity correction. No comparison survived correction when coarse-grid subsampling preceded smoothing. CONCLUSION: Boundary-anchored CT profiling identified postoperative frontal horn profile-shape changes supported by multiplicity-adjusted and sampling sensitivity analyses. Reproducibility was marker dependent, with repeatability limits exceeding mean early changes. These findings support further evaluation of the method as a quantitative research tool, with standardization and external validation required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Longitudinal boundary-anchored CT profiling of the frontal horns after cerebrospinal fluid shunting in idiopathic intracranial hypertension: a pilot study — Science Skim