RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

Spatially resolved periventricular ADC profiling in normal pressure hydrocephalus: an exploratory pilot study.

Malvina Garner, Frederik Fries, Christoph Garner, Alena Haußmann, Wolfgang Reith, Umut Yilmaz

Saarland University Hospital, Neuroradiology, Germany, Homburg.

Key points

From the paper's conclusion
  • Boundary-anchored ADC profiling identified persistent periventricular ADC differences and selected postoperative profile changes in NPH. The findings are exploratory and require validation.

Abstract

PURPOSE: To explore whether boundary-anchored apparent diffusion coefficient (ADC) profiling can characterize periventricular diffusion patterns in normal pressure hydrocephalus (NPH). MATERIALS AND METHODS: Seventeen patients with shunted NPH with baseline and postoperative follow-up ADC maps acquired at 1.5 T or 3 T and 17 age-, sex-, and scanner-matched controls were analyzed retrospectively. A short anchor was placed along the frontal horn ventricular boundary. ADC values were sampled along approximately orthogonal lines and summarized as amplitude- and shape-related profile metrics. Patient-control and longitudinal within-patient comparisons were analyzed with false-discovery-rate correction for multiple comparisons. RESULTS: At baseline, patients showed a higher reference ADC, inner-zone mean ADC, outer-zone mean ADC, and outer plateau ADC than controls. At follow-up, amplitude-related ADC differences persisted. Longitudinally, the profile multiphasicity index, inner peak ADC, and initial profile slope changed after shunting and remained significant after FDR correction, whereas most amplitude-related metrics remained stable. CONCLUSION: Boundary-anchored ADC profiling identified persistent periventricular ADC differences and selected postoperative profile changes in NPH. The findings are exploratory and require validation. KEY POINTS: · Boundary-anchored ADC profiling describes periventricular diffusion patterns in NPH.. · NPH showed persistent amplitude-related ADC differences versus matched controls.. · Selected shape-related profile metrics changed after shunt surgery.. · Findings are exploratory and require validation in larger cohorts.. CITATION FORMAT: · Garner M, Fries F, Garner C et al. Spatially resolved periventricular ADC profiling in normal pressure hydrocephalus: an exploratory pilot study. Rofo 2026; DOI 10.1055/a-2970-7054.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers