World neurosurgery

A Mixed-Reality Virtual-Monitor Workspace for Endoscopic Pituitary Surgery: Proof of Concept from Bench to Bedside.

Carlotta Fontana, Michele Guacci, Francesco Corrivetti, Anna Tortora, Luigi Falchetta, Vincenzo Meglio, Giuliana Panico, Giuseppe Carpenzano,

Department of Industrial Engineering, University of Salerno, 84084 Fisciano (SA), Italy. Electronic address: cfontana@unisa.it. · Department of Industrial Engineering, University of Salerno, 84084 Fisciano (SA), Italy.

Key points

From the paper's conclusion
  • A surgeon-centred mixed-reality workspace was feasible and well tolerated in both anatomical and live pituitary surgery. The findings support feasibility; whether workload was reduced was not assessed. Larger controlled studies incorporating objective measures of gaze, posture and workload are needed.

Abstract

OBJECTIVE: Endoscopic transsphenoidal pituitary surgery requires the management of an increasing amount of information: the surgeon must reconcile spatially separated operative screens - endoscopy, neuronavigation and preoperative imaging - each on its own monitor, away from the operative axis. To our knowledge, no three-source virtual-monitor workspace has been reported during live endoscopic pituitary surgery. This proof-of-concept study tested the workspace in the anatomy laboratory and in a first clinical case. METHODS: A custom mixed-reality platform was developed to integrate the endoscopic feed, neuronavigation data, and radiological imaging into the HoloLens 2 headset, where information was displayed through voice-controlled virtual monitors within the surgeon's field of view. Ten operators (five consultants, five second-year residents) performed standardised endoscopic endonasal procedures on a cadaveric specimen while wearing the headset. Perceived usability (SUS) and workload (SURG-TLX) were assessed. The platform was used by the lead surgeon during resection of a pituitary microadenoma. RESULTS: Laboratory SUS was 88 ± 6 and SURG-TLX weighted composite 38 ± 17 (0-100). In the clinical case the workspace was used through the nasal, sphenoidal and sellar stages without modifying the operative workflow or requiring removal of the headset (SUS 88; SURG-TLX 52). Situational stress, temporal demand and task complexity were rated highest; mental demand, physical demand and distractions lowest. CONCLUSIONS: A surgeon-centred mixed-reality workspace was feasible and well tolerated in both anatomical and live pituitary surgery. The findings support feasibility; whether workload was reduced was not assessed. Larger controlled studies incorporating objective measures of gaze, posture and workload are needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers