Veterinary anaesthesia and analgesia

Effects of dexmedetomidine on the minimum alveolar concentration and its derivatives in sevoflurane-anesthetized cats.

Wataru Ide, Yusuke Murahata, Yoko Konishi, Fuka Tokunaga, Mizuki Yokono, Yoshifumi Endo

Joint Graduate School of Veterinary Sciences, Tottori University, Tottori, Japan. · Joint Department of Veterinary Medicine, Faculty of Agriculture, Tottori University, Tottori, Japan. Electronic address: ymurahata@tottori-u.ac.jp.

Key points

From the paper's conclusion
  • Dexmedetomidine reduced the MAC and MAC derivatives in a plasma dexmedetomidine concentration-dependent manner in sevoflurane-anesthetized cats.

Abstract

OBJECTIVE: To evaluate the effects of dexmedetomidine on the sevoflurane minimum alveolar concentration (SEVMAC), minimum alveolar concentration (MAC) for blocking adrenergic responses (SEVMAC-BAR), and MAC for tracheal extubation (SEVMAC-Extubation). STUDY DESIGN: Prospective randomized, crossover experimental study. ANIMALS: Six healthy adult neutered cats [one female and five males; weighing 4.8 ± 1.1 kg (mean ± standard deviation)]. METHODS: Cats were anesthetized with sevoflurane in oxygen. After endotracheal intubation, anesthesia was maintained with sevoflurane and mechanical ventilation was performed. Each cat was given all six treatments in a random order, which were saline or dexmedetomidine infusions at maintenance doses of 0.15, 0.3, 0.6, 1.5, or 6.0 μg kg-1 hour-1, following respective loading doses of 1, 2, 4, 10, and 40 μg kg-1 over 20 minutes, designed to achieve an estimated plasma concentration of 0.5-20.0 ng mL-1. SEVMAC-BAR, SEVMAC and SEVMAC-Extubation were measured in this order. Plasma dexmedetomidine concentrations were determined using liquid chromatography-tandem mass spectrometry. A linear regression analysis was used to assess the plasma concentration-response relationships and estimate the half-maximal inhibitory concentration (IC50), defined as the plasma dexmedetomidine concentration producing a 50% reduction from the control value, separately for SEVMAC-BAR, SEVMAC, and SEVMAC-Extubation. RESULTS: The baseline SEVMAC-BAR, SEVMAC and SEVMAC-Extubation were 2.79 ± 0.86%, 2.65 ± 0.32%, and 1.60 ± 0.64%, respectively. These values significantly decreased in a plasma dexmedetomidine concentration-dependent manner. The IC50 values for SEVMAC-BAR, SEVMAC and SEVMAC-Extubation were 1.90 ng mL-1 [95% confidence interval (CI): 0.51-6.99 ng mL-1], 1.38 ng mL-1 (95% CI: 0.35-5.39 ng mL-1), and 2.24 ng mL-1 (95% CI: 0.67-7.50 ng mL-1), respectively. CONCLUSIONS: Dexmedetomidine reduced the MAC and MAC derivatives in a plasma dexmedetomidine concentration-dependent manner in sevoflurane-anesthetized cats. CLINICAL RELEVANCE: Dexmedetomidine could be effective in suppressing motor and sympathetic responses accompanied by noxious stimulation and maintaining endotracheal intubation in cats.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers