Is the bulbocavernosus reflex reliable under dexmedetomidine administration in children? -An analysis during tethered cord surgery.
Michika Ryu, Hiroshi Kokubun, Takako Hara, Tomoko Tochiki, Goichiro Tamura, Yuji Kitamura, Tadashi Miyagawa
Department of Pediatric Neurosurgery, Matsudo City General Hospital, Chiba, Japan. · Department of Anesthesiology, Matsudo City General Hospital, Chiba, Japan.
Key points
From the paper's conclusion- DEX suppresses BCR monitoring in a concentration-dependent manner during pediatric spinal untethering surgery. A predicted plasma concentration of approximately 0.67 ng/mL may represent a critical threshold for reliable BCR monitoring, although prospective validation using direct blood sampling is required.
Abstract
OBJECTIVE: Dexmedetomidine (DEX) is increasingly utilized in pediatric anesthesia; however, its impact on the bulbocavernosus reflex (BCR) remains unclear. The objective of this study was to elucidate the suppressive effects of DEX on the BCR and to establish a safe therapeutic window for its administration during pediatric spinal untethering surgery. METHODS: A retrospective two-stage investigation was conducted, enrolling 66 children. Cohort 1 (exploratory, n = 46) aimed to identify independent risk factors for BCR attenuation under standard anesthesia where DEX was initiated before dural opening. Multivariate analysis was performed to distinguish DEX effects from other variables. Cohort 2 (pharmacodynamic, n = 20) was designed to validate findings and define the safety threshold; DEX was administered after dural closure to isolate pharmacological effects from surgical manipulation. We analyzed the correlation between predicted plasma DEX concentrations (Potts model) and BCR amplitude using logistic regression. RESULTS: Cohort 1 identified DEX administration as the sole independent risk factor associated with BCR amplitude decline (p = 0.01), whereas others showed no significant impact. Cohort 2 confirmed a specific concentration-dependent suppression. A statistically significant amplitude reduction was observed starting 12 min after initiation. Logistic regression identified a critical inflection point at 0.67 ng/mL in predicted plasma concentration, around which BCR reliability was significantly compromised (p = 0.005). CONCLUSIONS: DEX suppresses BCR monitoring in a concentration-dependent manner during pediatric spinal untethering surgery. A predicted plasma concentration of approximately 0.67 ng/mL may represent a critical threshold for reliable BCR monitoring, although prospective validation using direct blood sampling is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Perineural versus Intravenous Dexmedetomidine for Ultrasound-guided Costoclavicular Brachial Plexus Block: A Randomized Controlled Trial.Journal of medical ultrasound · 2026
- Haemodynamic and Respiratory Effects of Dexmedetomidine as an Adjuvant to Oxycodone Patient‐Controlled Analgesia After Lumbar Spinal Fusion: A Post Hoc Analysis of the DoseRespDex Randomised Controlled TrialActa Anaesthesiologica Scandinavica · 2026
- Clinical efficacy and safety evaluation of dexmedetomidine hydrochloride nasal spray for sedation before examinations in children aged 2 to 6 years: protocol for a randomized controlled trial.Frontiers in pediatrics · 2026
- Dexmedetomidine vs. midazolam at single low doses for opioid and muscle relaxant-free anesthesia in pediatric dentistry: a randomized control trial.Frontiers in surgery · 2026
- Systematic understanding of acute effects of dexmedetomidine on rat carotid sinus baroreflex-mediated sympathetic arterial pressure regulation.American journal of physiology. Regulatory, integrative and comparative physiology · 2026
- Effects of Perioperative Intranasal Dexmedetomidine Spray on Clinical Outcomes of Pulsed Radiofrequency in Patients with Zoster-Associated Pain: A Randomized Controlled Trial.Journal of pain research · 2026