Comparison of Von Frey Filaments and Electronic Von Frey Device in Healthy dogs - a Prospective, randomized, experimental study.

Alexandra Schütter, Lena Bennmann, Stefanie Brause, Vanessa Rupp, Fritjof Freise, Sabine Kästner

University of Veterinary Medicine Hannover, Small Animal Clinic Bünteweg 9, 30559 Hannover. Electronic address: Alexandra.schuetter@tiho-hannover.de. · University of Veterinary Medicine Hannover, Small Animal Clinic Bünteweg 9, 30559 Hannover.

Randomised

Key points

From the paper's conclusion
  • Therefore, it was aimed to compare usage of EVF and VFM in healthy dogs in terms of inter-rater and inter-device reliability.

Abstract

Quantitative sensory testing (QST) using Von Frey Monofilaments (VFM) is established for assessing mechanical sensitivity in dogs. Alternatively, an Electronic Von Frey device (EVF) is available. At present no direct method comparison with both devices has been conducted in dogs. Therefore, it was aimed to compare usage of EVF and VFM in healthy dogs in terms of inter-rater and inter-device reliability. Further the influence of clipping on results gained and a possible correlation between body weight and sensory threshold should be assessed. In a prospective, randomized experimental study, with four raters VFM and EVF were compared in 61 healthy dogs (18 male, 6 male neutered, 25 female, 12 female spayed) at four anatomical locations across three appointments. Agreement between VFM and EVF was poor across all three appointments (ICC = 0.282-0.285). Inter-rater ICCs were poor for both methods, ranging from 0.25 to 0.34 for VFM and from 0.21 to 0.25 for EVF. Mixed-model analyses revealed significant effects of rater, dog type, anatomical location, and body weight for both devices (p < 0.0001). No significant effect of fur clipping on thresholds was detected for either method. EVF measurements were significantly shorter in duration than VFM (p < 0.001). The two devices do not represent the same test modality and cannot be used interchangeably. Device- and site-specific reference values should be established separately for each method. Given the poor interrater reliability, consistent rater training and the use of a single rater are essential in both clinical and research settings.

Read the paper