Talanta

A one-pot natural deep eutectic solvent-based extraction/purification method coupled with HPLC-FLD for the simultaneous determination of five bisphenols, bisphenol A diglycidyl ether and 4-nonylphenol in solid food.

Lucia Croce, Davide Fabiano, Diego Centonze

Department of Medical and Surgical Sciences, University of Foggia, Via Napoli 25, 71122, Foggia, Italy. Electronic address: lucia.croce@unifg.it. · Department of Agricultural Sciences, Food, Natural Resources and Engineering, Via Napoli 25, 71122, Foggia, Italy.

Key points

From the paper's conclusion
  • This work aimed to develop, optimize and validate a NADES-based extraction/purification method, coupled with RP-HPLC-FLD, for the simultaneous determination of five BPs, BADGE and 4-NP in solid food matrices, using fresh carrot as model matrix.

Abstract

Bisphenols (BPs), bisphenol A diglycidyl ether (BADGE) and 4-nonylphenol (4-NP) are contaminants that can migrate from food-contact plastic packaging into foodstuffs, raising toxicological concerns given their endocrine-disrupting potential. Natural deep eutectic solvents (NADESs) offer a greener alternative to conventional solvents, yet their application to these compounds in solid foods remains largely unexplored. This work aimed to develop, optimize and validate a NADES-based extraction/purification method, coupled with RP-HPLC-FLD, for the simultaneous determination of five BPs, BADGE and 4-NP in solid food matrices, using fresh carrot as model matrix. First, investigative experiments were used to establish suitable chromatographic and extraction conditions for an initial protocol, which was then optimized using a multivariate approach combining a D-optimal design, principal component analysis, and a Pareto front, and validated following the ICH Q2 (R2) guideline. Calibration curves were linear (R2 > 0.99) over 1-100 μg L-1, with LODs and LOQs ranging from 0.6 to 7.4 and from 1.9 to 22.4 μg L-1, respectively. Six of the seven analytes met the acceptance criteria of Regulation (EU) 2021/808, with recoveries of 80-112% and intra- and inter-day precision (CV) ≤ 16%. The method's practicality, environmental impact and analytical performance were assessed following the White Analytical Chemistry concept, using the Blue Applicability Grade Index (BAGI), AGREEprep, and the Red Analytical Performance Index (RAPI). To our knowledge, this is the first NADES-based method for the simultaneous determination of five BPs, BADGE and 4-NP in a solid food matrix, obtained with a direct, one-pot procedure and no additional purification step.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers