GO-TSC composite integrated with EDXRF for ultrasensitive determination of trace Hg(II) in water via solid-phase preconcentration.
Can Cheng, Bo Wang, Wenbao Jia, Yan Zhang, Hailou Jiang, Qing Shan, Yongsheng Ling
College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, 211816, China. · Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China. Electronic address: wangbo0819@nuaa.edu.cn.
Key points
From the paper's conclusion- This platform integrates selective enrichment, matrix simplification, and portable detection, offering a practical solution for on-site trace Hg monitoring.
Abstract
Conventional laboratory methods such as ICP-MS and AAS require complex pretreatment, lengthy analysis, and expensive instrumentation, making them inadequate for rapid on-site mercury monitoring. Although Energy-Dispersive X-ray Fluorescence (EDXRF) is a promising field-deployable technique, its direct application to liquid samples faces three critical challenges: (1) strong absorption and scattering of X-rays by the aqueous matrix severely reduce excitation efficiency, limiting detection limits to only the mg L-1 level-far above the 1 μg L-1 regulatory requirement; (2) complex and variable water matrices cause pronounced matrix effects that compromise quantitative accuracy; (3) mercury's volatility and chemical instability in liquid samples complicate preservation and introduce bias. To overcome these limitations, this study proposes a GO-TSC/thin-layer EDXRF enrichment strategy. Carboxyl dimine-grafted S/N ligand-modified graphene oxide (GO-TSC) adsorbent selectively captures Hg2+ via HSAB soft-soft coordination. Enrichment followed by vacuum filtration forms a uniform thin film, eliminating water attenuation. Optimized conditions (pH 3, 70 °C, 40 min; Rh target 9 W, 300 s) with Compton-scattering normalization effectively correct for deposition nonuniformity. The method exhibits a linear range of 10-8000 μg L-1 (R2 > 0.9928) and an LOD of 0.26 μg L-1 (≈3 orders of magnitude lower than direct measurement). RSD < 3.2%, strong anti-interference (coexisting ions at 4 ppm yield < 5% signal change), and 7-day signal loss < 4.5%. Notably, the LOQ of 0.87 μg L-1 is below the WHO permissible limit of 1.0 μg L-1, confirming that the method can accurately quantify Hg(II) at the regulatory borderline. Wastewater spike recoveries are 96.55-102.84%, in agreement with ICP-MS. This platform integrates selective enrichment, matrix simplification, and portable detection, offering a practical solution for on-site trace Hg monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrochemical Detection of Hg(II) Using EASA-Derived Glutathione-Modified Mesoporous Silica FilmsChemistry · 2026
- A Ratiometric Multimode Optical Sensor for Highly Selective and Sensitive Detection of Harmful Heavy Metal Hg²⁺ in Freshwater and SeawaterAnalytical Chemistry · 2025
- Ultra-trace mercury determination in drinking water by APGD-OES with cold vapor generation and gold trap enrichment.Talanta · 2026
- Mercury vapor generation using a non-equilibrium cold atmospheric plasma jet for mercury determination equipped with atomic absorption spectrometry.RSC advances · 2026
- Metallic film coated - magnetite and multiwalled carbon nanotube nanocomposite sensor for picomolar Hg monitoring in environmental samples.Journal of hazardous materials · 2026
- GO/AuNSs-functionalized hollow annular-core fiber SERS sensor for sensitive detection of trace Hg2+ in sweat.Talanta · 2026