On-chip liquid phase microextraction integrated with a COF-modified electrochemical sensor for trace determination of morphine in urine.
Maryam Mehrban, Tayyebeh Madrakian, Abbas Afkhami, Amir Mahdi Tavassoli, Hossein Khalilian, Mohammad Ali Zolfigol
Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran. · Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran. Electronic address: afkhami@basu.ac.ir.
Key points
From the paper's conclusion- The efficacy of the proposed method for the preconcentration and quantification of morphine in urine samples was thoroughly examined.
Abstract
This study presents a novel design of a millifluidic chip that integrates liquid phase microextraction with analyte detection through an electrochemical sensor. Upon incorporating the sample solution that includes the model analyte, morphine, into the donor part of the millifluidic chip, passive diffusion occurs as it traverses the supported liquid membrane, influenced by the pH gradient. The innovative sensor utilizes a platinum electrode (Pt) that is modified with a synthesized covalent organic framework (COF) based on 4,4'-methylenedianiline and 4,4',4''-((1,3,5-triazine-2,4,6-triyl) tris(oxy)) tribenzaldehyde (MDA-Trz-COF, referred to as MDA-Trz-COF/Pt. Following the extraction duration in the acceptor part, a differential pulse voltammetry determination of morphine was conducted. The parameters influencing the electrochemical-liquid phase microextraction (LPME) chip were refined through one-variable-at-a-time and central composite design methodologies. In ideal circumstances, the maximum current responses were observed during the oxidation of morphine on the MDA-Trz-COF/Pt electrode versus various concentrations of morphine within two distinct linear ranges of 5.0-120.0 and 120.0-700.0 pmol L-1, with a limit of detection of 1.5 pmol L-1 and a limit of quantification of 5.0 pmol L-1, respectively. The efficacy of the proposed method for the preconcentration and quantification of morphine in urine samples was thoroughly examined.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanistic Insights into Morphine Electrooxidation on Morphology-Controlled Cu/Co3O4@Graphene Nanoplatelet Nanocomposites: Experimental Validation and DFT AnalysisACS Applied Nano Materials · 2026
- A New Method to Enhance Electrochemiluminescence of Imine-Based Covalent Organic FrameworksJournal of the American Chemical Society · 2025
- Visible light-mediated synthesis of metal-free molecularly imprinted polymers for highly selective creatinine detection.International journal of biological macromolecules · 2026
- Development of a thiol-ene microfluidic chip for CE-MS of peptides and proteins.Analytical and bioanalytical chemistry · 2026
- Nanoconfinement catalysis-enhanced electrochemiluminescence aptasensor for the sensitive detection of matrix metalloproteinase-9RSC Advances · 2026
- High-sensitive determination of midazolam in urine samples using hydrogen peroxide-free enhanced electrochemiluminescence sensor based on modified polypyrrole/carbon paste electrode.Analytical and bioanalytical chemistry · 2026