Portable microcontroller-based impedance analyzer equipped with molecularly imprinted polymer for sensitive and specific detection of amyloid beta.
Juthamas Hongoeb, Kamonrat Phopin, Tanawut Tantimongcolwat, Waralee Ruankham, Subhas Chandra Mukhopadhyay
School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW, 2109, Australia; Center for Research Innovation and Biomedical Informatics, Faculty of Medical Technology, Mahidol University, Bangkok, 10700, Thailand. · Center for Research Innovation and Biomedical Informatics, Faculty of Medical Technology, Mahidol University, Bangkok, 10700, Thailand; Department of Clinical Microbiology and Applied Technology, Faculty of Medical Technology, Mahidol University, Bangkok, 10700, Thailand. Electronic address: kamonrat.php@mahidol.ac.th.
Key points
From the paper's conclusion- As a proof-of-concept achieved with only a 15-min analysis, this study offers a sensitive, portable, and cost-effective platform that shows promise for decentralized screening applications, thereby holding the potential to significantly improve patient outcomes.
Abstract
Alzheimer's disease (AD) is a progressive neurodegenerative condition with a rising global prevalence. Although clinical immunoassays offer high sensitivity, their dependence on costly and centralized infrastructure hinders widespread screening in resource-limited regions. Herein, we developed an electrical sensing platform utilizing molecularly imprinted polymers (MIPs) as synthetic receptors to detect a critical biomarker, amyloid beta 40 (Aβ40). The analytical performance was evaluated using impedance measurements through a high-precision benchtop LCR meter and a cost-effective miniaturized impedance evaluation board. This biomimetic sensor enabled sensitive detection of Aβ40 across a tested concentration range of 0.01 - 10 pg/mL with a correlation coefficient (R2) ≥ 0.98 for both impedance devices. Notably, the miniaturized board demonstrated strong parity with the benchtop system, yielding limit of detection (LOD) values of 0.19 pg/mL for the miniaturized board and 0.12 pg/mL for the benchtop LCR meter. Furthermore, spiked analysis in human serum and artificial cerebrospinal fluid (aCSF) showed relative errors below 10% at all tested concentrations. As a proof-of-concept achieved with only a 15-min analysis, this study offers a sensitive, portable, and cost-effective platform that shows promise for decentralized screening applications, thereby holding the potential to significantly improve patient outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel ratiometric molecularly imprinted electrochemical microsensor with synergistic embedded signal and surface reference probes for non-electroactive Aβ42 detection.Journal of hazardous materials · 2026
- C-Terminal Epitope-Imprinted Polymer-Coated Electrodes for Selective Sensing of β-Amyloid Peptide 42.Biosensors · 2026
- NanoGold-enhanced biomimetic sensor for Tau-441 protein detection in serum for Alzheimer's disease diagnosisBioelectrochemistry · 2026
- Electrochemical Quantification of Salivary Amyloid-β1–42 Using Disposable Gold Screen-Printed Electrodes: Analytical Validation and Comparison with ELISAACS Omega · 2026
- High-Performance Screen-Printed OECT-Inspired with Encased Cassette Based on PEDOT:GO for Sensitive and Specific Electrochemical Aptasensing of Aβ-42 in Management of Alzheimer's Disease.ACS applied bio materials · 2026
- Affinity peptide-based microfluidic electrochemical system for ultrasensitive detection of amyloid-β peptides.Biosensors & bioelectronics · 2026