A novel ratiometric molecularly imprinted electrochemical microsensor with synergistic embedded signal and surface reference probes for non-electroactive Aβ42 detection.
Zimei Yu, Xue Kong, Xingying Chen, Mingde Huang, Dongmei Tang, Ziang Ye, Haiyang Guo, Zheng-Zhi Yin
Jiaxing Key Laboratory of Molecular Recognition and Sensing, Provincial Key Laboratory of Multimodal Perceiving and Intelligent Systems, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, China; Engineering Research Center of Intelligent Human Health Situation Awareness of Zhejiang Province, Jiaxing University, 314001, China. · Department of Clinical Laboratory, Jiaxing Hospital of Traditional Chinese Medicine Affiliated to Jiaxing University, Jiaxing, China.
Key points
From the paper's conclusion- On the AN, an acid chrome blue K-electropolymerized imprinted layer serves as the recognition unit, embedded hemin acts as the Aβ42-modulated signal probe, and surface caffeic acid (CA) serves as the internal reference, forming a common-interface ratiometric system.
Abstract
Ratiometric molecularly imprinted electrochemical sensors (RMIESs) can mitigate electroactive surface area effects, background interference, and signal fluctuations while enhancing anti-interference capability and stability, but reported sensors are mainly suitable for electroactive targets. Herein, a novel RMIES strategy using an acupuncture needle (AN) was demonstrated for the non-electroactive biomarker β-amyloid1-42 (Aβ42). On the AN, an acid chrome blue K-electropolymerized imprinted layer serves as the recognition unit, embedded hemin acts as the Aβ42-modulated signal probe, and surface caffeic acid (CA) serves as the internal reference, forming a common-interface ratiometric system. CA was employed for the first time as an electroactive internal reference probe. The hemin-CA peak potential difference is 600 mV in differential pulse voltammetry, sufficient for ratiometric electroanalysis. This ratiometric microsensor exhibits a wide linear detection range (0.1 ∼ 5 × 106 pg/mL) and a low detection limit (0.0104 pg/mL) for Aβ42. Compared with the single-signal built-in sensor, it shows superior detection performance, anti-interference capability, and reproducibility. Furthermore, an AN-based microelectrode electrochemical system was explored and used on pig brain tissue. This microsensor provides a novel ratiometric electroanalysis strategy for non-electroactive biomarkers and is suitable for integration because it avoids external mediators, enables miniaturization, and allows multifunctional integration with acupuncture.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- C-Terminal Epitope-Imprinted Polymer-Coated Electrodes for Selective Sensing of β-Amyloid Peptide 42.Biosensors · 2026
- Portable microcontroller-based impedance analyzer equipped with molecularly imprinted polymer for sensitive and specific detection of amyloid beta.Talanta · 2026
- A versatile multi-dimensional ratiometric sensor exploiting material-interface properties for t-Tau protein detection in human serum.Talanta · 2026
- Simultaneous Electrochemical Detection of NGF and proNGF Under Native Conditions Using Molecularly Imprinted Polymers: Toward Point‐of‐Care Diagnosis of Alzheimer's DiseaseAdvanced Healthcare Materials · 2026
- NanoGold-enhanced biomimetic sensor for Tau-441 protein detection in serum for Alzheimer's disease diagnosisBioelectrochemistry · 2026
- Sensitive detection of amyloid-β42 using a graphitic carbon nitride-boosted electrochemical peptide biosensor.Mikrochimica acta · 2026