Epitope-imprinted nanoparticles prepared by controlled solid-phase synthesis for low-nanomolar-affinity SARS-CoV-2 spike recognition and direct non-faradaic impedance sensing in oral fluid.
Amaia Alday-Izaguirre, Lucía Diez-Caballero, Ainhoa Elejaga-Jimeno, Gontzal García Del Caño, Antonio Guerreiro, Ramón J Barrio, Nora Unceta, Alberto Gómez-Caballero
Department of Analytical Chemistry, Faculty of Pharmacy, University of the Basque Country EHU, Vitoria-Gasteiz, 01006, Spain; Bioaraba, MetaboloMIPs, Vitoria-Gasteiz, 01008, Spain. · Department of Analytical Chemistry, Faculty of Pharmacy, University of the Basque Country EHU, Vitoria-Gasteiz, 01006, Spain.
Key points
From the paper's conclusion- Herein we present molecularly imprinted nanoparticles (MIN) as synthetic antibodies with nanomolar affinity (4.57 ± 0.01 nM) targeting the spike protein of the SARS-CoV-2.
Abstract
Herein we present molecularly imprinted nanoparticles (MIN) as synthetic antibodies with nanomolar affinity (4.57 ± 0.01 nM) targeting the spike protein of the SARS-CoV-2. The peptide corresponding to the residues 470-TEIYQAGST-478 was selected as the template to produce nanoparticles via solid-phase epitope imprinting, using a water-soluble photocleavable iniferter. MIN with different monomer compositions were screened by surface plasmon resonance (SPR) to identify the formulation with the highest affinity for the target protein, finding that the monomer N-(4-hydroxyphenyl) acrylamide (HPAm) made a significant contribution to achieving high affinity binding. Morphological and physicochemical analysis of the nanoparticles revealed irregular, spherical particles with diameters of 130.7 ± 9.4 nm with zeta potential values of 33.2 ± 57.4 mV. MIN were immobilised on interdigitated gold electrodes to fabricate sensors for spike protein detection based on non-faradaic impedance, simplifying the sensing protocol by eliminating the need for redox probes and reference electrodes, making it more suitable for point-of-care (PoC) applications. The sensor proved capable of directly determining the target protein in diluted samples without any further preparation, exhibiting a LOD and a LOQ of 15.3 pM and 35.7 pM, respectively, in oral fluid. Sensor selectivity was demonstrated through a competitive assay using the target peptide, its scrambled sequence (IYTATQGES), and the envelope protein as competitors, with only the target peptide showing significant competition. The methodology presented here constitutes a versatile platform with that can be readily extended to peptides derived from other viruses for the development of new miniaturised PoC devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Portable D-Shaped POF-SPR Sensor Integrated with NanoMIPs for High-Affinity Detection of the SARS-CoV-2 RBD ProteinApplied Sciences · 2026
- Multiplexed Detection of Respiratory Viruses Using Surface Plasmon Resonance Spectroscopy With Ultrathin Carbon Nanomembranes.Advanced healthcare materials · 2026
- Novel paper-based electrochemical system for detection of anti-spike protein antibodies from SARS-CoV-2Microchimica Acta · 2026
- Affinity Peptide-Engineered Magnetic Microswimmers for Ultrafast On-the-Fly Screening of Influenza A Virus in Microliter-Scale Samples.ACS sensors · 2026
- Wearable In Situ SERS Sensors Based on the Metal@MOF Particle-in-Cavity Model: Suitable for Detection of Multifarious Biomarkers in Different Biofluids of HumansACS Sensors · 2026
- Multimodal LFIA platform integrating visual readout, smartphone grayscale imaging and surface-enhanced Raman scattering for point-of-care detection of SARS-CoV-2 protein.Analytical methods : advancing methods and applications · 2026