Matrix conditioning and magnetic bead target transfer for fluorescence aptamer-CRISPR/Cas12a detection of kanamycin in river water.
Tianyi Yang, Xiaoping Yu, Jian Wu
College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China. · College of Life Sciences, China Jiliang University, Hangzhou, 310018, China. Electronic address: yxp@cjlu.edu.cn.
Key points
From the paper's conclusion- These results demonstrate that combining matrix conditioning with magnetic bead target transfer improves the matrix compatibility of fluorescence aptamer-CRISPR/Cas12a detection for trace KAN analysis in environmental water.
Abstract
Fluorescence aptamer-CRISPR/Cas12a assays provide efficient signal conversion and amplification for the detection of small molecules. However, their practical application in complex environmental water remains limited. Matrix components can cause signal loss before CRISPR amplification. In this study, a fluorescence aptamer-CRISPR/Cas12a assay was developed by integrating matrix conditioning and magnetic bead target transfer for kanamycin (KAN) detection in complex water matrices. Matrix conditioning reduced interference from humic acid (HA) and inorganic ions, while magnetic bead target transfer captured KAN and transferred it into a small volume of eluate. The transferred KAN induced aptamer release from aptamer/complementary strand duplexes on streptavidin magnetic beads. The released aptamer activated reporter cleavage by Cas12a and generated an increased fluorescence response. In a model matrix containing HA and inorganic ions, the assay produced only weak responses to KAN without matrix conditioning. In contrast, the workflow with matrix conditioning produced a clear increase in response with KAN concentration. In the conditioned model matrix, the assay achieved a linear response over 0.4-4 nM with a limit of detection (LOD) of 0.4 nM. This LOD was below the proposed predicted no-effect concentration (PNEC) for KAN in river water. Recoveries of 90-105% were obtained in spiked real river water samples, supporting its applicability to real water analysis. These results demonstrate that combining matrix conditioning with magnetic bead target transfer improves the matrix compatibility of fluorescence aptamer-CRISPR/Cas12a detection for trace KAN analysis in environmental water.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A CRISPR-Cas12a Fluorescent Aptasensor for Point-of-Care Drug Concentration Detection: A Synergistic Regulation by DNA Aptamer and RNA BlockerAnalytical Chemistry · 2025
- CRISPR/Cas12a-Based Aptasensor for Cas9 Protein Detection in Spiked Food Matrices.Molecules (Basel, Switzerland) · 2026
- Aptamer-Based Fluorescent Biosensors for Kanamycin Detection in Food Systems: Design Strategies, Sensing Mechanisms, and Practical Applications.Foods (Basel, Switzerland) · 2026
- Cell-Surface-to-Solution Signal Transduction via a CRISPR/Cas12a-Based Dual-Target Aptamer Sensor for Detecting Urothelial Carcinoma Cells in Urine.Analytical chemistry · 2026
- An aptamer-regulated CRISPR/Cas12a system based on split crRNA for theophylline and tobramycin detection.Analytical methods : advancing methods and applications · 2026
- CRISPR-Enhanced Colorimetric Aptasensor for Adenosine Triphosphate Detection Based on MoS2-Based NanozymesBiosensors · 2025