Vortex-assisted matrix solid-phase dispersion for the determination of Cu, Mn, and Zn in maize by high-resolution continuum source atomic absorption spectrometry.
Ana C B Luckow, Lisliane Kickofel, Kaiane Q Ribeiro, Ana L Q S Santos, Letícia C M Saldanha, Paola C Crestani, Andressa D W V Martinez, Fábio A Duarte,
Integrated Analysis Center, Federal University of Rio Grande, Rio Grande, RS, 96203-900, Brazil; School of Chemistry and Food, Federal University of Rio Grande, Rio Grande, RS, 96203-900, Brazil. · Department of Chemistry, Federal University of Santa Maria, Santa Maria, RS, 97105-900, Brazil.
Key points
From the paper's conclusion- This study reports, for the first time, the development of an environmentally friendly analytical strategy based on vortex-assisted matrix solid-phase dispersion (VA-MSPD) combined with high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) for the determination of Cu and Mn (using graphite furnace atomization) and Zn (using flame atomization) in maize (Zea mays L.) samples.
Abstract
This study reports, for the first time, the development of an environmentally friendly analytical strategy based on vortex-assisted matrix solid-phase dispersion (VA-MSPD) combined with high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) for the determination of Cu and Mn (using graphite furnace atomization) and Zn (using flame atomization) in maize (Zea mays L.) samples. The optimized MSPD conditions were 0.5 g of sample, 0.5 g of diatomaceous earth (DE) as the solid support, 3 min of maceration, 10 mL of ultrapure water as the extraction solution, 3 min of vortex mixing, and 10 min of centrifugation. The graphite furnace temperature program was optimized with pyrolysis temperature of 1100 °C for Cu and 1200 °C for Mn, and atomization temperatures of 2000 °C for Cu and 2200 °C for Mn. The limits of quantification were 0.18, 0.61, and 3.6 μg g-1 for Cu, Mn, and Zn, respectively. Accuracy was evaluated by results comparison with those achieved after microwave-assisted digestion (MAD) and detection by inductively coupled plasma optical emission spectrometry (ICP-OES), showing agreement ranging from 84 to 116%. Analyte concentrations ranged from 0.43 to 2.0 μg g-1 for Cu, from 1.1 to 6.8 μg g-1 for Mn, and from 8.6 to 27 μg g-1 for Zn, with relative standard deviations below 10%. The AGREE and AGREEprep metrics yielded scores of 0.66 and 0.74 for VA-MSPD/HR-CS GF AAS, 0.67 and 0.71 for VA-MSPD/HR-CS F AAS, and 0.54 and 0.33 for MAD/ICP-OES, respectively, demonstrating a greater environmental sustainability of the proposed methods compared with the conventional digestion-based procedure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Magnetite-based SPME-SQT-FAAS for trace chromium determination in riceScientific Reports · 2026
- Visible–Near-Infrared Spectroscopy for Rapid Mineral Screening in Corn Silage to Support Precision Animal NutritionAgriculture · 2026
- B-052 Automation of sample preparation workflow for trace elements testing by ICP-MS/MSClinical Chemistry · 2026
- A Greener Acid-free Microwave-Assisted Digestion Method for Multielement Analysis of Fish Tissues by ICP-MS.ACS omega · 2026
- Detection of Cd2+ and Pb2+ in egg yolk and maize samples by a novel SDA/MWCNTs-based electrochemical sensor.RSC advances · 2026
- Fabrication of MIL-88B(Co/Fe)/Ti3C2Tx nanocomposite for the vortex-assisted dispersive micro-solid phase extraction of Cu(II), Cd(II), and Pb(II) in edible grains and wastewater via flame atomic absorption spectrometry.Food chemistry · 2026