A Greener Acid-free Microwave-Assisted Digestion Method for Multielement Analysis of Fish Tissues by ICP-MS.
Marcos V S Pereira, Elisânia K B Fonseca, Jemmyson R de Jesus, Marco A Z Arruda
Research Laboratory in Bionanomaterials, LPbio, Department of Chemistry, Federal University of Viçosa - UFV 36570-900, Viçosa, Minas Gerais, Brazil. · Group of Spectrometry, Sample Preparation and Mechanization, GEPAM, Department of Analytical Chemistry, Institute of Chemistry, University of Campinas - UNICAMP 13083-970, Campinas, São Paulo, Brazil.
Key points
From the paper's conclusion- In this study, an acid-free microwave-assisted digestion (AFMAD) method based exclusively on H2O2 was developed and optimized for multielement determination in fish tissues by ICP–MS.
Abstract
Trace element monitoring in fish tissues requires reliable and sustainable sample preparation methods, particularly for complex biological matrices. In this study, an acid-free microwave-assisted digestion (AFMAD) method based exclusively on H2O2 was developed and optimized for multielement determination in fish tissues by ICP-MS. A central composite design coupled with response surface methodology was employed to evaluate the influence of H2O2 concentration, ramp time, and digestion temperature on matrix decomposition efficiency using 100 mg of dry fish tissue subsamples throughout the method development. The optimized conditions consisted of 30% (v/v)-H2O2, 8 min ramp time, a 20 min hold time and 240 °C, resulting in residual carbon contents below 20%, which indicates efficient oxidation of the organic matrix using H2O2 in the absence of HNO3. The analytical performance of the proposed method was evaluated using cod muscle certified reference material (BCR-422), providing recoveries ranging from 76 to 101% for Fe, Cu, Zn, Mn, As, and Cd. Excellent linearity was obtained for all analytes (R 2 > 0.990) within the 0-50 μg L-1 range. Limits of detection ranged from 0.0004 to 0.04 μg g-1, demonstrating suitable sensitivity for trace elemental analysis in fish matrices. The applicability of the method was demonstrated through the analysis of five commercial fish species collected in the Mariana-MG region. Concentrations of toxic elements were found in Megaleporinus conirostris (Cd, 0.003 mg kg-1) and Cichla ocellaris (As, 0.07 mg kg-1) and remained below the maximum limits established by Brazilian legislation. The proposed AFMAD method demonstrated satisfactory analytical performance for complex fish matrices while eliminating the use of concentrated mineral acids, reducing hazardous reagent consumption, and improving the sustainability characteristics of sample preparation procedures for elemental analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determination of Cl, Br, and I by ICP-MS using diluted acid: an environmentally friendly strategy for food analysis.Talanta · 2026
- Quantitative Detection of Toxic Elements in Food Samples by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)Processes · 2025
- Microwave-assisted sample preparation: A review of 50 years of achievements and trendsAnalytica Chimica Acta · 2026
- A standardized protocol for microplastic and non-synthetic microfiber extraction and µFTIR identification in elasmobranch gastrointestinal tissuesMethodsX · 2026
- Anhydrous magnesium sulfate-assisted electroextraction enables non-matrix-matched quantification of six sulfonamides across diverse animal-derived foods.Food chemistry · 2026
- A sequential H₂O₂–KOH digestion protocol for microplastic extraction from cured fish matrices: development, optimization and validationMicroplastics and Nanoplastics · 2026