Monitoring aeration during non-invasive ventilation in the delivery room: a narrative review of current and emerging methods.
M M Bloemhof, J Dekker, S J E Cramer, A B Te Pas
Willem-Alexander Children's Hospital, Department of Paediatrics, Division of Neonatology, Leiden University Medical Centre, Leiden, the Netherlands. Electronic address: m.m.bloemhof@lumc.nl. · Willem-Alexander Children's Hospital, Department of Paediatrics, Division of Neonatology, Leiden University Medical Centre, Leiden, the Netherlands. Electronic address: j.dekker@lumc.nl.
Key points
From the paper's conclusion- This narrative review evaluates nine monitoring methods for their ability to answer two key clinical questions: whether spontaneous breathing is present and effective, and whether positive pressure ventilation results in effective lung aeration.
Abstract
Ensuring effective lung aeration during non-invasive ventilation in the delivery room is a central challenge in neonatal resuscitation. Preterm neonates frequently require respiratory support at birth, yet it is difficult to assess whether delivered ventilation is effectively reaching the lungs. Currently recommended monitoring parameters reflect mostly indirect physiological responses to lung aeration and provide limited actionable guidance when values fail to improve. This narrative review evaluates nine monitoring methods for their ability to answer two key clinical questions: whether spontaneous breathing is present and effective, and whether positive pressure ventilation results in effective lung aeration. Methods are grouped by measurement modality: respiratory flow and pressure monitoring, exhaled carbon dioxide (CO2) detection, lung ultrasound, thoracic volume change, and transcutaneous diaphragmatic electromyography. Each method provides clinically relevant physiological information, yet for most, limitations in reliability, interpretability, or delivery room applicability constrain their use as an actionable guide during active resuscitation. Of all modalities reviewed, exhaled CO2 comes closest to addressing both clinical questions, as its presence directly confirms gas exchange and therefore lung aeration by either spontaneous breathing or ventilation, though evidence for its use to guide resuscitation remains limited. Delivery room evidence remains sparse across most methods, and where studies exist, they have largely been conducted for post-hoc physiological analysis rather than evaluation of real-time guidance. Future research should focus on prospective evaluation of monitoring-guided resuscitation strategies and on identifying which combinations of methods provide the most actionable information without adding unnecessary complexity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bedside assessment of respiratory drive and effort: The role and limitations of non-invasive occlusion maneuvers.Journal of clinical anesthesia · 2026
- A passive thin-film mechanical device for visual respiratory monitoring during oxygen mask use: development and bench validation.Medical engineering & physics · 2026
- Impact of real-time respiratory function monitoring on neonatal mask ventilation training: a multicentre simulation-based crossover study.BMJ paediatrics open · 2026
- 40 Bedside flexible endoscopic evaluation of the swallow (FEES) in the neonatal intensive care unitPaediatrics & Child Health · 2026
- Use of respiratory oscillometry in infants: a scoping reviewPediatric Research · 2026
- Design and pilot clinical evaluation of a low-cost, continuous respiratory monitor for newbornsmedRxiv · 2026