Structural heart : the journal of the Heart Team

Procedural and Hemodynamic Outcomes of Contemporary Self-Expanding Valves for Transcatheter Aortic Valve Replacement: A Multicenter Comparison From the AMTRAC Registry.

Amos Levi, Yeela Talmor-Barkan, Marco Barbanti, Sofia Sammartino, Giuliano Costa, Carmelo Grasso, Ole De Backer, Davorka Lulic,

Department of Cardiology, Rabin Medical Centre, Petach-Tikva, Israel. · The Department of Medicine and Surgery, Università degli Studi di Enna Kore, Enna, Italy.

Observational · n=2,673

Key points

From the paper's conclusion
  • Contemporary self-expanding platforms demonstrate comparable 1-year mortality and stroke rates. Periprocedural vascular and bleeding safety profiles are strongly modulated by center-specific clustering and practice variations. Conversely, the superior hemodynamic performance of the Evolut platform remains independent of institutional factors. These findings support an anatomy-driven approach to valve selection integrating patient profiles with institutional practices.

Abstract

BACKGROUND: Comparative data among contemporary self-expanding transcatheter heart valve designs remain limited. We compared clinical and hemodynamic outcomes following transcatheter aortic valve replacement using 2 leading contemporary platforms. METHODS: This multicenter cohort study utilized the AMTRAC registry to evaluate consecutive patients treated with either Evolut PRO/PRO+/FX or Navitor. The primary analysis employed a 1:1 propensity score-matched cohort, utilizing multilevel mixed-effects models to adjust for center-level clustering. The primary endpoint was 1-year all-cause mortality. RESULTS: Of 2673 patients, propensity score matching yielded a balanced cohort of 1200 patients. At 1-year, all-cause mortality was similar between groups (Navitor: 7.1% vs. Evolut: 9.2%; hazard ratio 0.75; 95% CI: 0.47-1.21; p = 0.24). In-hospital mortality (0.8%), periprocedural stroke (2.3%), permanent pacemaker implantation (Navitor: 14.4% vs. Evolut: 15.9%; p = 0.554), and paravalvular leak (p = 0.221) were comparable. Initial differences showing lower vascular and bleeding events with Navitor were completely attenuated after accounting for center-level clustering (vascular: p = 0.838; bleeding: p = 0.745). Conversely, postprocedural mean transaortic gradient was lower with Evolut (7.3 ± 3.9 mmHg vs. 8.6 ± 4.1 mmHg; p < 0.001), a hemodynamic advantage that remained highly robust after center adjustment (odds ratio 2.43; 95% CI: 1.66-3.58; p < 0.001). Sensitivity analyses yielded consistent results. CONCLUSIONS: Contemporary self-expanding platforms demonstrate comparable 1-year mortality and stroke rates. Periprocedural vascular and bleeding safety profiles are strongly modulated by center-specific clustering and practice variations. Conversely, the superior hemodynamic performance of the Evolut platform remains independent of institutional factors. These findings support an anatomy-driven approach to valve selection integrating patient profiles with institutional practices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers