Stroke After Transcatheter Aortic Valve Replacement With Contemporary Valves: Insights From the OCEAN-TAVI Registry.
Yusuke Watanabe, Masanori Yamamoto, Hirofumi Hioki, Masafumi Saito, Jo Omiya, Kento Kito, Yasuyuki Tsuchida, Yosei Iseki,
Department of Cardiology, Teikyo University School of Medicine, Tokyo, Japan. · Department of Cardiology, Toyohashi Heart Center, Toyohashi, Japan.
Key points
From the paper's conclusion- In-hospital stroke remains an important complication after contemporary TAVR and is associated with worse clinical outcomes. Differences in stroke incidence across valve types were observed, highlighting the need for improved risk assessment.
Abstract
BACKGROUND: Stroke remains a serious complication after transcatheter aortic valve replacement (TAVR), even with contemporary devices. The objective of the study was to evaluate the incidence, predictors, and prognosis of in-hospital stroke in patients undergoing TAVR with contemporary valve platforms. METHODS: We analyzed 5123 patients from the multicenter OCEAN-TAVI registry who underwent TAVR with SAPIEN 3 Ultra RESILIA, Evolut FX, or Navitor between May 2022 and December 2024. Stroke incidence across valve types was compared using inverse probability of treatment weighting (IPTW). Predictors were assessed using multivariable Firth penalized logistic regression. RESULTS: In-hospital stroke occurred in 2.5% of patients. After IPTW adjustment, stroke incidence differed among valve types: 1.7% of patients treated with SAPIEN 3 Ultra RESILIA (S3UR), 4.5% with Evolut FX, and 2.4% with Navitor (p = 0.044). Disabling stroke was more frequent with Evolut FX (2.5%) compared with S3UR (0.4%) and Navitor (0.7%; p < 0.001). Self-expanding valve use (adjusted odds ratio [aOR] 2.64, 95% CI 1.67-4.16 for Evolut FX; aOR 2.37, 95% CI 1.35-4.18 for Navitor; both vs. S3UR), prior stroke (aOR 1.83, 95% CI 1.19-2.73), reduced renal function, and nontransfemoral access (aOR 2.11, 95% CI 1.29-3.45) were independently associated with in-hospital stroke. One-year survival was significantly lower among patients with stroke than among those without stroke (73.0% vs. 90.3%; p < 0.001). CONCLUSIONS: In-hospital stroke remains an important complication after contemporary TAVR and is associated with worse clinical outcomes. Differences in stroke incidence across valve types were observed, highlighting the need for improved risk assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stroke Risk After TAVR: Balloon-Expandable vs Self-Expanding Valves in Community Practice.JACC. Advances · 2026
- Pooled Periprocedural and Short-Term Outcomes After Transcatheter Aortic Valve Replacement With Contemporary Self-Expanding Valves: A Systematic Review and Meta-Analysis.Structural heart : the journal of the Heart Team · 2026
- Current Generation Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement: A Retrospective Multicenter Analysis.The Annals of thoracic surgery · 2026
- Differential Predictors of Early and Mid-to-Long Term Cerebrovascular Events Following Transcatheter Aortic Valve Implantation.Medicina (Kaunas, Lithuania) · 2026
- Short-Term Complications of Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis (PROLONG-TAVR).Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Procedural and Hemodynamic Outcomes of Contemporary Self-Expanding Valves for Transcatheter Aortic Valve Replacement: A Multicenter Comparison From the AMTRAC Registry.Structural heart : the journal of the Heart Team · 2026