Cuff-induced focal tracheomegaly managed with a custom silicone Y-Stent: A case report.
Christopher Yurosko, Michael Machuzak
Department of Medicine, University of Vermont, Burlington, VT, USA. · Pulmonary Department, Respiratory Institute, Cleveland Clinic, Cleveland, OH, USA.
Key points
From the paper's conclusion- Although generally safe, late complications, including tracheomalacia, tracheomegaly, and tracheal rupture, can occur with prolonged tracheostomy dependence.1 Acquired focal tracheal injury after tracheostomy is rare and likely underreported.2,3 We describe a case of chronic tracheostomy dependence complicated by cuff-induced tracheal injury, managed with a custom tracheobronchial silicone Y-stent
Abstract
Tracheostomy is commonly performed to secure the airway in patients requiring prolonged mechanical ventilation. Although generally safe, late complications, including tracheomalacia, tracheomegaly, and tracheal rupture, can occur with prolonged tracheostomy dependence.1 Acquired focal tracheal injury after tracheostomy is rare and likely underreported.2,3 We describe a case of chronic tracheostomy dependence complicated by cuff-induced tracheal injury, managed with a custom tracheobronchial silicone Y-stent. This case highlights the importance of cuff pressure monitoring and presents a novel approach to complex airway stabilization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Postoperative Controlled Ventilation in a Patient With Montgomery's T-Tube In Situ After Laryngotracheal Reconstruction: A Case Report.A&A practice · 2026
- Misconnection of Oxygen Tubing to the "Smart Cuff Manager" Causing Cuff Explosion: A Preventable Equipment Error.A&A practice · 2026
- Novel bronchoscopic technique using endoscopic scissors for retrieval of a 12-year-old silicone airway stent placed for a post-intubation tracheal stenosis: A case report.Lung India : official organ of Indian Chest Society · 2026
- Case report: complete pilot balloon detachment in a ventilator-dependent patient with high-risk tracheostomy exchange.Frontiers in medicine · 2026
- Tracheobronchial Replacement Using Cryopreserved Aortic Allografts: Results in 50 Patients (TRITON-01 Registry)European Journal of Cardio-Thoracic Surgery · 2025
- Mechanical interactions between airway stents and the airway wall: biomechanics, complications, and design optimizationJournal of Materials Science: Materials in Engineering · 2026