Resuscitation

Spectral Characteristics and Parameters of Pulse Oximetry Waveforms for Assessing Resuscitation Status.

Chen Li, Hanqi Tang, Jing Yang, Yanfen Chai, Xuezhong Yu, Shengyong Xu, Jun Xu

Department of Emergency, Tianjin Medical University General Hospital, Tianjin, China. · Department of Emergency, State Key Laboratory of Complex Severe and Rare Diseases, Critical and Emergency Pharmaceuticals & Medical Devices Innovation Lab, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.

Observational · n=451

Key points

From the paper's conclusion
  • Pulse oximetry plethysmography waveform analysis-using signals already available on standard monitors-may provide a non-invasive, real-time approach that may help identify ROSC during ongoing compressions and distinguish between stable and unstable circulation.

Abstract

BACKGROUND: Real-time assessment of physiological resuscitation status is critical for guiding personalised cardiopulmonary resuscitation (CPR) and avoiding unnecessary harm from prolonged chest compressions. Non-invasive, objectively trackable tools for this purpose remain limited. METHODS: This multicentre retrospective study (2013-2018) included 451 adult patients with cardiac arrest (497 CPR episodes) from 14 Chinese tertiary hospitals, comprising 158 Out-of-Hospital Cardiac Arrest (OHCA) episodes with prehospital SpO2/ECG monitoring continued upon ED arrival and full pulse oximetry plethysmography (POP)/ECG/end-tidal carbon dioxide (ETCO2) monitoring established in the ED, and 339 In-Hospital Cardiac Arrest (IHCA) episodes occurring in the ED. We analysed POP waveforms across four statuses: compression-only (CC), chest compression with return of spontaneous circulation (CC+ROSC, spontaneous circulation during ongoing compressions), non-compression without ROSC, and spontaneous circulation-only (SC). Time-domain (area under the POP curve [POPAUC]) and frequency-domain spectral features were evaluated against clinically documented ROSC. RESULTS: A frequency-domain "hybrid" pattern during the CC+ROSC identified ROSC with 100% specificity (PPV 1.000). In CC status,POPAUC was higher in stable-ROSC than unstable-ROSC (3232.2±1008.2 vs. 2769.6±1013.0 PVPG, P=0.007). The POPAUC was lower in CC+ROSC status than in SC status for stable-ROSC (2768.2±997.8 vs. 3335.8±842.4 PVPG, P=0.001), but the reverse was observed for unstable-ROSC (2697.5±941.0 vs. 1338.1±952.6 PVPG, P<0.001). POP waveforms disappearance with concurrent ECG presence identified pulseless electrical activity with 100% specificity. CONCLUSION: Pulse oximetry plethysmography waveform analysis-using signals already available on standard monitors-may provide a non-invasive, real-time approach that may help identify ROSC during ongoing compressions and distinguish between stable and unstable circulation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers