Fractal-dimension-based quantification of CT micronodules for classifying borderline pneumoconiosis.
Noboru Niki, Yoshiki Kawata, Yasutaka Nakano, Hiroaki Sakai, Tsuyoshi Oguma, Yoshinori Ohtsuka, Takumi Kishimoto, Kazuto Ashizawa
Division of Science and Technology, Graduate School of Sciences and Technology for Innovation, Tokushima University, 2-1, Minamijosanjima-cho, Tokushima, 770-8506, Japan. · Institute of Post-LED Photonics, Tokushima University, 2-1, Minamijosanjima-cho, Tokushima, 770-8506, Japan. Electronic address: kawata@tokushima-u.ac.jp.
Key points
From the paper's conclusion- Micronodule count combined with fractal dimension achieved high internal discrimination for classifying borderline CT categories. External validation and automation are needed to assess generalizability.
Abstract
BACKGROUND: Distinguishing category 0/1 from 1/0-1/1 on CT is subject to reader variability. We developed a method combining micronodule count with fractal analysis. METHODS: We analyzed three-dimensional chest CT images from 48 individuals with coal workers' pneumoconiosis or silicosis, read by consensus using ICOERD. Lung lobes were segmented with software and micronodules manually segmented. For each lobe, we computed micronodule count and fractal dimension from micronodule masks. Features were aggregated as the most affected lobe, defined by highest micronodule count, and as a count-weighted whole-lung average. A linear-kernel support vector machine was evaluated with 5-fold stratified group cross-validation. Discrimination was summarized by AUC and AP, and calibration by Brier score, calibration slope, and intercept. A prespecified count-alone comparator using the whole-lung total micronodule count was assessed on the same folds. RESULTS: Combining fractal dimension with count yielded high discrimination between 0/1 and 1/0-1/1. For most-affected-lobe aggregation, AUC was 0.972 (95% CI, 0.927-1.000) and AP was 0.975; for whole-lung aggregation, AUC was 0.965 (95% CI, 0.921-1.000) and AP was 0.973; for the count-alone comparator, AUC was 0.917 (95% CI, 0.842-0.993) and AP was 0.947. Calibration was numerically favorable for the combined models in terms of Brier score and calibration slope. CONCLUSIONS: Micronodule count combined with fractal dimension achieved high internal discrimination for classifying borderline CT categories. External validation and automation are needed to assess generalizability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative CT parameters and imaging features for differentiating non-invasive from invasive pathology in surgically resected pulmonary micronodules: a retrospective studyBMC Pulmonary Medicine · 2026
- Development and internal validation of a chest CT radiomics model for identifying pneumoconiosis.Journal of thoracic disease · 2026
- Photon-counting Detector CT Spectral Reconstructions for Radiomics-based Liver Lesion ClassificationInvestigative Radiology · 2026
- Evaluation of a radiomics workflow in chest CT: a pilot study of lung lesion segmentation, feature extraction, and clustering.Radiologia brasileira · 2026
- Quantitative CT features for COPD classification and GOLD spirometric severity assessment: a single-center model-development study.Frontiers in medicine · 2026
- Association of dual-energy CT-derived quantitative parameters with hydroxyproline levels and pulmonary function in nonspecific interstitial pneumoniaFrontiers in Immunology · 2026