Clinical workflow optimisation through advanced practice radiation therapist-led cone-beam computed tomography image matching in thoracic stereotactic body radiotherapy.
M T B Pawi, S Y Sin, W L Ng, T R Siow, Y Q Li, A Thiagarajan, K W Fong, S P Yap,
Division of Radiation Oncology, National Cancer Centre Singapore, 30 Hospital Boulevard, Singapore, 168583, Singapore. Electronic address: muhd.tarmizi.pawi@nccs.com.sg. · Division of Radiation Oncology, National Cancer Centre Singapore, 30 Hospital Boulevard, Singapore, 168583, Singapore.
Key points
From the paper's conclusion- Credentialed APRT-led CBCT image matching was feasible within thoracic SBRT and did not materially prolong workflow duration.
Abstract
INTRODUCTION: Thoracic stereotactic body radiotherapy (SBRT) requires accurate image verification because of high dose per fraction, steep dose gradients and tight treatment margins. In many departments, cone-beam computed tomography (CBCT) image matching remains dependent on radiation oncologist (RO) availability, which may contribute to workflow delays and inefficient use of specialist clinical time. This clinical workflow evaluation examined whether credentialed advanced practice radiation therapist (APRT)-led CBCT image matching could maintain workflow efficiency while reducing immediate RO attendance requirements. METHODS: Routine operational workflow data were extracted for thoracic SBRT fractions delivered between October 2025 and May 2026. All Day 1 fractions were excluded from the primary comparison, irrespective of matching personnel. Non-Day 1 RO-led and APRT-led fractions were compared for patient in-room duration, personnel attendance duration, workflow variability, documented protocol deviations, image-matching failures, workflow disruptions and estimated direct manpower cost. RESULTS: A total of 362 fractions from 89 treatment courses were analysed, including 89 Day 1 fractions, 170 RO-led non-Day 1 fractions and 103 APRT-led non-Day 1 fractions. In the primary non-Day 1 analysis, median patient in-room duration was 19 min for RO-led fractions and 20 min for APRT-led fractions. Median image-matching duration was 11 min and 13 min, respectively. No APRT-related protocol deviations, image-matching failures or workflow disruptions were documented in the reviewed treatment records. Annualised projections indicated approximately 31.3 physician-hours released and SGD 1864 in direct manpower cost savings per year. CONCLUSION: Credentialed APRT-led CBCT image matching was feasible within thoracic SBRT and did not materially prolong workflow duration. IMPLICATIONS FOR PRACTICE: Structured credentialing, Day 1 collaborative review, defined escalation criteria and ongoing audit may support safe APRT-led image verification in high-precision radiotherapy workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Skill mix redesign in Italian radiation oncology: A technical note on advanced practice radiation therapists.Radiography (London, England : 1995) · 2026
- Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCTJournal of Applied Clinical Medical Physics · 2026
- Implementation of an FMEA-guided quality-improvement workflow is associated with improved setup accuracy in lung stereotactic body radiotherapy.Frontiers in oncology · 2026
- A real-time image-guided six-degree-of-freedom internal-external correlation framework for motion monitoring on a standard linear accelerator.Physics in medicine and biology · 2026
- Dynamic proton arc therapy sequencing optimization algorithm for brain stereotactic radiosurgery.Physics in medicine and biology · 2026
- EP09.29 Image-guided intraoperative radiotherapy for resectable brain metastases: Prospective evaluation of dosimetric accuracy and clinical outcomesNeuro-Oncology · 2026