X-ray image quality before and after radiographer commenting: A quantitative visual grading characteristics analysis.
A Tonks, F Gray, D Nocum, Y Jimenez, A Tavakoli Taba, E Ekpo
Medical Image Optimisation and Perception Group, Discipline of Medical Imaging Science, Susan Wakil Health Building, Western Ave, Camperdown, NSW, 2050, Australia. Electronic address: alexandra.tonks@sydney.edu.au. · Medical Image Optimisation and Perception Group, Discipline of Medical Imaging Science, Susan Wakil Health Building, Western Ave, Camperdown, NSW, 2050, Australia.
Key points
From the paper's conclusion- Quantitative evidence demonstrates implementation of RCA significantly improves the overall quality of projection radiographs submitted for reporting.
Abstract
INTRODUCTION: The Radiographer Comment and Alert (RCA) model was established to provide written alerts of abnormal radiographic appearances identified at acquisition, but its quantitative impact on image quality is unknown. This study quantifies differences in radiograph image quality before and after RCA implementation. METHODS: A total of 234 radiographs encompassing the pelvis, hand, wrist, elbow, knee, ankle, and foot were collected. This comprised all 117 investigations for these anatomical areas with radiographer comments over 12-months at one site, and 117 matched radiographs obtained one year before RCA implementation. Each image pair was displayed simultaneously, but the order and left-right orientation was randomised. Seventeen radiographers independently rated image pairs using a visual grading characteristics (VGC) analysis scale on seven quality criteria (rotation, angulation, centering, collimation, exposure, artifacts, diagnostic utility). Data were analysed using VGC Analyser Software v1.0.2. Non-parametric rank-invariant statistics generated an area under the VGC curve (AUCVGC) to measure the difference in quality between images with and without radiographer comments. RESULTS: Across the combined dataset, images acquired after implementation of RCA received visual grading ratings for radiological quality that were significantly higher than images acquired prior to implementation (AUCVGC0.52, p = 0.016, CI[0.500862,0.532967]). Statistical significance at 95% confidence was not met for individual upper (AUCVGC0.52, p = 0.084) and lower limb (AUCVGC0.50, p = 0.746) regions, but was achieved for the axial region (AUCVGC0.54, p = 0.012). Quality improvement was driven by improved positioning, particularly rotation (AUCVGC0.57, p = 0.002). Intraclass correlation coefficient scores were good or excellent (ICC3,k ≳ 0.62-0.97) and all reached significance (p-value<0.05), indicating stable consensus and good inter-rater agreement. CONCLUSION: Quantitative evidence demonstrates implementation of RCA significantly improves the overall quality of projection radiographs submitted for reporting. IMPLICATIONS FOR PRACTICE: Radiographer image interpretation models can be utilised as tools to improve radiographic image quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- More than a comment: Radiographers' perspectives on image interpretation and image qualityRadiography · 2026
- Interobserver and intra-observer agreement among radiographers in assessing the quality of chest radiograph.The Medical journal of Malaysia · 2026
- Quality and Determinants of Inpatient Imaging Requests: A Multicentre RI-RADS Study.Academic radiology · 2026
- U-Net-Based Automated Quality Control of Knee Radiographs: Dual-Center Validation and Clinical Intervention.Journal of imaging informatics in medicine · 2026
- Quality assessment of radiographs through AI-driven feedback: A randomized comparative study on radiographer response in lateral knee radiographs.Radiography (London, England : 1995) · 2026
- Outpatient radiology imaging request quality using the reason for exam imaging reporting and data system (RI-RADS): A multicentre quality audit.European journal of radiology · 2026