Reliability and measurement error of a climbing-specific upper extremity testing battery for sports rehabilitation monitoring.
Uzo Ehiogu, Hang Ng, Matthew Buckthorp, Stephen Patterson
Royal Orthopaedic Hospital Birmingham Education and Training Department, United Kingdom; University of Birmingham Medical School, United Kingdom; St Marys University Centre for Applied Performance Sciences, United Kingdom; Depot Climbing Centre Birmingham Inside Edge Physiotherapy, United Kingdom. Electronic address: uzo.ehiogu@nhs.net. · Depot Climbing Centre Birmingham Inside Edge Physiotherapy, United Kingdom; Sandwell and West Birmingham NHS Trust, United Kingdom.
Key points
From the paper's conclusion- Climbing-specific finger and shoulder strength testing is a reliable reassessment tool. Mean work force was the most stable endurance-derived outcome. MDC95 values provide preliminary thresholds for interpreting whether observed change exceeds measurement error during rehabilitation monitoring.
Abstract
OBJECTIVE: To establish the inter-tester, test-retest reliability and measurement properties of a climbing-specific upper extremity testing battery for clinical use. DESIGN: Repeated measures study. SETTING: Sports injury clinic. PARTICIPANTS: Thirty recreational boulderers. MAIN OUTCOME MEASURES: Finger and shoulder peak force, mean work force, area under the curve (AUC), time to failure, repetitions to failure and fatigue index. STATISTICAL ANALYSIS: Intraclass correlation coefficients (ICC 2,1), standard error of measurement (SEM), minimal detectable change at 95% confidence level (MDC95), coefficient of variation (CV%) and Bland-Altman limits of agreement plots. RESULTS: Finger and shoulder pull strength demonstrated excellent test-retest reliability (ICC 0.96-0.98). Finger strength MDC95 values ranged from 4.8 to 6.7 kg. Shoulder strength MDC95 ranged from 5.5 to 5.8 kg. Inter-rater reliability was excellent for finger strength (ICC 0.96-0.97) and shoulder strength (ICC 0.96). Mean work force for finger endurance was (ICC 0.99) and shoulder endurance (ICC 0.93-0.99), while time to failure, repetitions to failure, AUC and fatigue index demonstrated greater variability. CONCLUSION: Climbing-specific finger and shoulder strength testing is a reliable reassessment tool. Mean work force was the most stable endurance-derived outcome. MDC95 values provide preliminary thresholds for interpreting whether observed change exceeds measurement error during rehabilitation monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sufficient Standardization? Evaluating the Reliability of an Inertial Sensor (BeyondTM) for Ankle Dorsiflexion After a Brief Familiarization PeriodSports · 2025
- Digital handgrip assessment in musculoskeletal health: reliability, measurement precision, interchangeability, and clinical implications for rehabilitation and sports medicineBMC Sports Science, Medicine and Rehabilitation · 2026
- Reliability of a functional electromechanical dynamometer for a bilateral standing press exercise at intensities of 30% and 60% of isometric peak force in trained women.PeerJ · 2026
- Test-Retest Reliability of Hierarchical Proprioception Assessment of the WristmedRxiv · 2026
- History-dependent force production during functional multi-digit finger flexion: evidence from a climbing-relevant half-crimp task.Sports biomechanics · 2026
- Test–Retest Reliability and Convergent Validity of the 6-Minute Pegboard and Ring Test in Obese IndividualsMeasurement in Physical Education and Exercise Science · 2025