Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine

Test-retest reliability and the minimal detectable change of clinical and structural outcomes in athletes with patellar tendinopathy.

Mikkel Holm Hjortshoej, Syed Zahra Gillani, René Brüggebusch Svensson, S Peter Magnusson, Anne-Sofie Agergaard

Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark; Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark; Department of Physical and Occupational Therapy, Copenhagen University Hospital - Bispebjerg-Frederiksberg Hospital, Copenhagen, Denmark; University College Absalon, Centre of Health and Rehabilitation, Slagelse, Denmark. · Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark; Center for Healthy Aging, Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

Key points

From the paper's conclusion
  • The SLDS, VISA-P, PPT, tendon thickness, and PD activity demonstrated good-to-excellent relative reliability in individuals with PT; however, absolute measurement precision was limited.

Abstract

OBJECTIVES: To establish test-retest reliability and minimal detectable change (MDC) values for outcomes in patients with patellar tendinopathy. DESIGN: Test-retest reliability study. SETTING: Hospital. PARTICIPANTS: Thirty participants (29.6 years, 77% males) underwent two test days with a 7-day hiatus. MAIN OUTCOME MEASURES: Single-leg decline squat (SLDS), VISA-P, pain pressure threshold (PPT), and ultrasound measurements (tendon thickness and Power Doppler (PD) activity). Data was analyzed using intraclass correlation coefficient (ICC) and MDC performed on standard deviation (SD) of pooled and change scores. RESULTS: The SLDS showed ICC values ranging from 0.86 to 0.92 with a MDC95 ranging from 0.91 to 2.46 on the numeric rating scale for SDchange and SDpooled. For the VISA-P, the ICC was 0.93 with a MDC95 of 6.05 and 11.81 for SDchange and SDpooled. PPT resulted in an ICC of 0.91 and MDC95 of 69.37 and 117.06 kPa for SDchange and SDpooled. Tendon thickness showed an ICC of 0.98 and MDC95 of 0.29 and 1.01 mm for SDchange and SDpooled. PD activity showed an ICC of 0.80, and MDC95 of 11.95 and 18.78 mm2 for SDchange and SDpooled. CONCLUSIONS: The SLDS, VISA-P, PPT, tendon thickness, and PD activity demonstrated good-to-excellent relative reliability in individuals with PT; however, absolute measurement precision was limited.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers