Trigger-based adaptive proton therapy and changes in target coverage and cardiac dose in esophageal cancer.
Vlad Badiu, Esther Kneepkens, Dominique Reijtenbagh, Maaike Berbée, Richard Canters
Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, Netherlands.
Key points
From the paper's conclusion- Trigger-based adaptive IMPT improved cumulative target coverage and cardiac sparing without increasing lung dose. Target underdose and cardiac overdose triggers provided complementary benefits, supporting their use in structured adaptive replanning.
Abstract
BACKGROUND AND PURPOSE: Inter-fractional anatomical variations during proton therapy for esophageal cancer may compromise target coverage and increase dose to surrounding organs. Adaptive replanning can mitigate these effects, but its cumulative dose-based and clinical impact remains insufficiently characterized. We evaluated offline adaptive intensity-modulated proton therapy (IMPT) triggered by target underdose or cardiac overdose using deformable dose accumulation. MATERIALS AND METHODS: A retrospective cohort of 192 esophageal cancer patients treated with IMPT was analyzed. Eighty-five underwent adaptive replanning and 107 were treated non-adaptively. Dose accumulation was performed by assigning each fraction to the closest weekly repeat computed tomography (CT) scan and deformably mapping doses to the planning CT. Accumulated doses from adapted and non-adapted plans were compared for internal target volume (ITV) and gross tumor volume (GTV) coverage, target hotspots, heart and lung dose, and normal tissue complication probability (NTCP) for 2-year post-treatment mortality. RESULTS: Compared with the non-adaptive treatment scenario, the adaptive scenario increased ITV D98% by 1.9 percentage points (pp) and GTV D98% by 0.8 pp. in the target underdose subgroup. In the cardiac overdose subgroup, mean heart dose decreased by 1.0 Gy and heart V40Gy by 1.7 pp., with no increase in mean lung dose. NTCP for 2-year post-treatment mortality decreased by 1.5 pp. in this subgroup. CONCLUSIONS: Trigger-based adaptive IMPT improved cumulative target coverage and cardiac sparing without increasing lung dose. Target underdose and cardiac overdose triggers provided complementary benefits, supporting their use in structured adaptive replanning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of accumulated target dose on tumor response in distal esophageal cancer treated with intensity-modulated proton therapy.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Dosimetric impact of CBCT-guided online adaptive stereotactic body radiotherapy for prostate cancer: a 250-fraction retrospective analysis.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026
- Interplay effect evaluation on lung and esophageal cancer patients treated with compact proton system in free breathing.Physics and imaging in radiation oncology · 2026
- Nominal plan robustness may predict plan degradation in proton therapy for oropharyngeal head‐and‐neck cancerJournal of Applied Clinical Medical Physics · 2026
- Impact of anatomical changes on simulated proton arc therapy and intensity‐modulated proton therapy for lung cancerJournal of Applied Clinical Medical Physics · 2026
- Patient selection for proton therapy in lung cancer: Updating and internal-external cross-validation of a normal tissue complication probability model for acute oesophageal toxicity.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2026