Specimen-Wise Evaluation of Acute Leukemia Subtyping Using Microscopic Hyperspectral Imaging.
Yilin Xiang, Jikuo Wang, An Guo Liu, Dejian Wei, Dawei Qiu, Xiaoqing Yang, Mengqiu Zhang
School of Medical Information Engineering, Shandong University of Traditional Chinese Medicine, Jinan, Shandong Province, China. · Gansu Provincial Earthquake Administration, Lanzhou, Gansu Province, China.
Key points
From the paper's conclusion- Quality-controlled visible/near-infrared microscopic hyperspectral signatures supported three-class discrimination under leakage-controlled specimen-wise validation. The analysis explicitly removes low-signal edge bands and provides PCA/loading and discriminant-analysis baselines in addition to the compact CNN.
Abstract
BACKGROUND: Microscopic hyperspectral imaging provides label-free, wavelength-resolved optical signatures that may support hematologic smear screening. We evaluated whether a compact spectral model could discriminate acute lymphoblastic leukemia, acute myeloid leukemia, and healthy controls while minimizing information leakage. METHODS: Hyperspectral microscopy acquired 128 bands over the nominal 370-980 nm detector range. After dark/white reference calibration, edge bands with poor signal-to-noise were excluded and downstream analyses were restricted to the usable 400-900 nm interval; no min-max normalization or SNV was applied after reflectance calibration. A compact one-dimensional convolutional neural network was evaluated on 48 bone-marrow smear specimens (acute lymphoblastic leukemia, n=18; acute myeloid leukemia, n=15; healthy controls, n=15) using specimen-wise stratified five-fold cross-validation. Pixel-level probabilities were aggregated to specimen-level predictions. RESULTS: After restricting the analysis to 400-900 nm, the model achieved an accuracy of 0.921±0.011, macro-F1 of 0.910±0.010, and macro-area under the receiver operating characteristic curve of 0.962±0.007. Principal component analysis showed class-related structure in the retained spectral window, and cross-validated PCA-LDA provided a lower-complexity comparator for sensitivity, specificity, and accuracy. CONCLUSION: Quality-controlled visible/near-infrared microscopic hyperspectral signatures supported three-class discrimination under leakage-controlled specimen-wise validation. The analysis explicitly removes low-signal edge bands and provides PCA/loading and discriminant-analysis baselines in addition to the compact CNN.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hyperspectral Histopathology with Spectral-Spatial Multiple-Instance Learning for Acute Leukemia Classification.Photodiagnosis and photodynamic therapy · 2026
- Patient-level visible-near-infrared hyperspectral histopathology for normal skin, actinic keratosis, and cutaneous squamous cell carcinoma.Photodiagnosis and photodynamic therapy · 2026
- Patient-Level Hyperspectral State-Space Learning for Melanoma Pathology Diagnosis.Photodiagnosis and photodynamic therapy · 2026
- Microscopic hyperspectral discrimination of triple-negative and HER2-positive breast cancer in routine hematoxylin-eosin sections.Photodiagnosis and photodynamic therapy · 2026
- An Artificial Intelligence Framework for Detection of Leukemia with Comparison Between Segmented and Non-Segmented Images.Sensors (Basel, Switzerland) · 2026
- A leakage-controlled multiscale contextual involution-inception framework for spectral-spatial classification of neonatal hyperspectral images.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026