Photodiagnosis and photodynamic therapy

Hyperspectral Histopathology with Spectral-Spatial Multiple-Instance Learning for Acute Leukemia Classification.

Weiqing Xu, Yao Qin, Ling Liu, Zhe Ma

The First Affiliated Hospital of Dali University, Dali, Yunnan 671000, China. · Department of Rehabilitation Medicine, Jinan Third People's Hospital, Jinan, Shandong, China.

Observational · n=78

Key points

From the paper's conclusion
  • Microscopic HSI combined with the newly developed HemaSpec-MIL framework enabled accurate internal differentiation of AML, ALL, and normal marrow while preserving wavelength- and tissue-level interpretability. Independent multicenter validation and acquisition harmonization are required before clinical translation.

Abstract

BACKGROUND: Acute myeloid leukemia (AML) and acute lymphoblastic leukemia (ALL) may show overlapping morphology on bone-marrow trephine sections, while definitive ancillary testing is not always immediately available. We evaluated whether microscopic hyperspectral imaging (HSI) combined with patient-level spectral-spatial deep learning could support differentiation of AML, ALL, and normal marrow. METHODS: This retrospective single-center study included 78 patients (26 AML, 26 ALL, and 26 normal marrow). H&E-stained bone-marrow trephine sections were imaged across 400-1000 nm. Patient-level nested stratified five-fold cross-validation was defined before region-of-interest (ROI) sampling to prevent information leakage. We developed HemaSpec-MIL, a new hierarchical spectral-spatial multiple-instance learning algorithm and a major methodological output of this study. The framework combines multi-scale spectral encoding, morphology encoding, bidirectional cross-attention, and gated multiple-instance aggregation to generate patient-level probabilities. The primary endpoint was pooled out-of-fold macro-AUC. RESULTS: HemaSpec-MIL achieved a pooled out-of-fold accuracy of 0.897, macro-F1 of 0.897, and macro-AUC of 0.957. One-vs-rest AUCs were 0.964 for AML, 0.945 for ALL, and 0.962 for normal marrow. Performance exceeded spectral-only, morphology-only, 3D-CNN, Vision Transformer, and spectral Transformer baselines. Ablation analysis supported complementary contributions from the spectral branch, morphology branch, cross-attention fusion, gated patient-level aggregation, and spectral augmentation. CONCLUSIONS: Microscopic HSI combined with the newly developed HemaSpec-MIL framework enabled accurate internal differentiation of AML, ALL, and normal marrow while preserving wavelength- and tissue-level interpretability. Independent multicenter validation and acquisition harmonization are required before clinical translation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers