Production of no-carrier-added theranostic Au-199: A systematic evaluation of liquid-liquid extraction from dissolved neutron-irradiated platinum targets.
Martin Pressler, Stefan Zeman, Christoph Denk, Graeme J Stasiuk, Hannes Mikula, Veronika Rosecker
Institute of Applied Synthetic Chemistry, TU Wien, Austria; Center for Labelling and Isotope Production, TRIGA Center Atominsitut, TU Wien, Austria. · Institute of Applied Synthetic Chemistry, TU Wien, Austria.
Key points
From the paper's conclusion- Our optimised process removes the need for chelating agents and back-extraction yielding n.c.a. 199Au in high molar activity and radionuclidic purity ready for small-molecule radiolabelling. Over 95% of platinum target could be recycled which reduces waste and is expected to increase molar activity in subsequent production cycles.
Abstract
INTRODUCTION: 199Au (half-life 3.14 d) is of high interest as medical isotope due to its potential use in theranostic applications. It is produced indirectly via neutron capture of 198Pt to form 199Pt which subsequently decays by β--emission to 199Au. Separation of no-carrier-added 199Au from irradiated natPt target material remains challenging. METHODS: A systematic screening of five solvents (toluene, dichloromethane, ethyl acetate, diethyl ether, methyl tertbutyl ether) across five different HCl concentrations (0.1, 0.5, 1.0, 5.0, 7.5 M) for the liquid-liquid extraction of 199Au from irradiated natPt was performed. KD values for 199Au and Pt were calculated based on γ-spectroscopy measurements. Additionally, the influence of container vials (glass vs. polypropylene) and recovery of Pt target material were investigated. RESULTS: Significant differences between extraction in glass and polypropylene vials were found. Although higher KD values were observed in polypropylene vials, this was attributed to leaching of extractant-active compounds from the polypropylene vials. Therefore, extraction in glass vials from 5 M HCl with diethyl ether was found to be optimal, whereas ethyl acetate was disqualified due to Pt co-extraction and acid hydrolysis. Using this condition, we obtained 98% of 199Au in two extraction steps with a high molar activity of 40 MBq/nmol and high radionuclidic purity of 99.8%. CONCLUSION: Our optimised process removes the need for chelating agents and back-extraction yielding n.c.a. 199Au in high molar activity and radionuclidic purity ready for small-molecule radiolabelling. Over 95% of platinum target could be recycled which reduces waste and is expected to increase molar activity in subsequent production cycles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of solid phase extractants TEVA and TK200 for the separation of medically relevant 199Au from thermal neutron irradiated Pt target.Journal of chromatography. A · 2026
- Production and radiochemical processing of 191Pt from proton-irradiated natural iridium foils.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Purification of a Au tracer from a Pt target using UTEVA resin column chromatography.Journal of chromatography. A · 2026
- Improved 140Nd Production for the 140Nd/140Pr In Vivo Generator through Target Recycling and Radiochemical Optimization.ACS omega · 2026
- High-resolution neodymium isolation from adjacent lanthanides by synergistic extraction chromatography for nuclear fuel burnup analysis.Journal of chromatography. A · 2026
- Production and quality control of no-carrier-added 161Tb from enriched 160Gd target material.EJNMMI radiopharmacy and chemistry · 2026