Microvascular oxygenation responses are associated with the reactive hyperemic stimulus but not brachial artery flow-mediated dilation.
Kase J Pennartz, Ethan Hein, Justin D Sprick, Joshua L Keller
Applied Physiology Laboratory, Department of Kinesiology, Health Promotion and Recreation, School of Health Sciences, College of Health and Public Service, University of North Texas, TX, USA. · Applied Physiology Laboratory, Department of Kinesiology, Health Promotion and Recreation, School of Health Sciences, College of Health and Public Service, University of North Texas, TX, USA. Electronic address: Joshua.keller@unt.edu.
Key points
From the paper's conclusion- These findings suggest that NIRS-derived metrics represent distinct yet complementary measures to FMD, while the association between StO2max and SR AUC suggests a relationship between microvascular function and the shear stimulus underlying FMD.
Abstract
Microvascular responses contribute to the post-occlusive shear rate stimulus (quantified as the area under the curve [SR AUC]) that precedes flow-mediated dilation (FMD). While FMD is measured via ultrasonography, near-infrared spectroscopy (NIRS) characterizes aspects of microvascular function; however, the extent to which NIRS-derived indices relate to FMD remains unclear. Therefore, this investigation examined the associations between NIRS-derived metrics and peak hyperemic velocity (PHV), FMD, and SR AUC in 20 healthy adults. Skeletal muscle tissue oxygenation (StO2) was assessed using NIRS during a vascular occlusion test, while brachial artery diameter and blood velocity were measured using duplex ultrasound. NIRS-derived measures included the rate of resaturation (upslope), maximum resaturation (StO2max), and the area under the curve (AUC) of sustained hypersaturation. Pearson correlations and multiple linear regression were used to assess relationships between NIRS-derived measures, PHV, FMD, and SR AUC. There were no observed significant associations between NIRS-derived metrics and FMD (p > 0.08). In contrast, StO2max was significantly related to PHV (r = 0.530, p = 0.016) and SR AUC (r = 0.629; p = 0.004), and independently predicted SR AUC (β = 0.632, t = 3.893, p = 0.001). Baseline artery diameter (p = 0.346), SR AUC (p = 0.153), and upslope (p = 0.790) did not predict FMD (R = 0.668, adjusted R2 = 0.336, F(3,15) = 4.03, p = 0.027). These findings suggest that NIRS-derived metrics represent distinct yet complementary measures to FMD, while the association between StO2max and SR AUC suggests a relationship between microvascular function and the shear stimulus underlying FMD.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Near-infrared spectroscopy for estimating mixed venous oxygen saturation and cardiac output during off-pump coronary artery bypass grafting: a prospective observational study.Journal of clinical monitoring and computing · 2026
- Sex differences and acute intermittent isometric handgrip exercise effects on microvascular reactivity in young healthy adults.Frontiers in physiology · 2026
- Impact of NIRS-IVUS-identified lipid-rich plaques on microvascular resistance reserve after PCIEuropean Heart Journal · 2026
- Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin FluorescenceNMR in Biomedicine · 2026
- The RFR-FFR delta: a novel physiological signature of microvascular dysfunction and long-term mortality in patients undergoing LAD PCIEuropean Heart Journal · 2026
- Quantitative analysis of tissue oxygenation trajectories in DIEP flaps using near infrared spectroscopy: A retrospective cohort study.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026