Comparative evaluation of clinical efficacy of two fixed functional appliances for treating skeletal class II malocclusion: A randomized controlled trial.
Saugat Ray, D C Chaudhary, Sanjeev Datana, Vishvaroop Nagpal, S S Agarwal
Reader & Instructor (Orthodontics & Dentofacial Orthopedics), Armed Forces Medical College, Pune, India. · Dental Officer & Classified Specialist (Orthodontics & Dentofacial Orthopedics), MDC Secunderabad, India.
Key points
From the paper's conclusion- The authors conclude that post functional cephalometric changes for both the groups were similar. The duration taken for functional phase and time taken for appliance removal in Advansyc 2 was lesser than Forsus FRD.
Abstract
BACKGROUND: There exists limited literature on the comparison of Forsus fatigue-resistant device (Forsus FRD)TM and AdvansyncTM 2: The aim of this randomized Controlled Trial with Registration number CTRI/2021/01/030399, was to compare the clinical efficacy of Forsus FRD versus AdvanSync 2 in the treatment of Skeletal Class II malocclusion along with the differences in treatment duration, chairside time, patient comfort & operator's convenience and frequency of breakages of appliance. METHODS: Sixty samples after randomization were divided into two groups. Group I (Forsus FRD) and Group II (Advansync 2). The post functional cephalograms were taken (T1) and comparison of cephalometric data was done with pre-treatment records (T0). RESULTS: The differences between the cephalometric parameters at T0 and T1 were evaluated with Paired t- test. All the parameters showed statistically significant differences in both groups except SNA (in both Group I and II) and FMA (in Group II). Unpaired t-test reveals statistically insignificant differences between the groups except for lower lip protrusion with p = 0.001. Statistically significant reduction of the treatment time duration (p = 0.004) and chairside time for removal of appliance (p = 0.001) was observed. Mann Whitney U test was used for finding difference in operators' and patients' convenience and no statistically significant differences were observed between two groups. CONCLUSION: The authors conclude that post functional cephalometric changes for both the groups were similar. The duration taken for functional phase and time taken for appliance removal in Advansyc 2 was lesser than Forsus FRD.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation and comparison of airway changes in skeletal Class II patients treated with Twin Block and Forsus FRD: a systematic review.Frontiers in dental medicine · 2026
- Clinical and lateral cephalometric evaluation of class II elastic therapy in skeletal class II malocclusion cases indicated for fixed functional appliance: An in vivo study.Bioinformation · 2026
- Root resorption in Class II malocclusion treatment with various methods.BMC oral health · 2026
- Long-Term Stability of Class II Malocclusion Treatment With the Forsus Appliance: A Retrospective Clinical Study With Historical Normal-Occlusion Controls.Orthodontics & craniofacial research · 2026
- Clinical efficacy of aligners with mandibular advancement in treatment of Class II malocclusions compared to conventional functional appliances: A systematic review.Stomatologija · 2026
- Analysis of the efficacy of AngelAligner A6 mandibular advancer and Twin Block in the treatment of class II malocclusion in growing patients: a prospective clinical study.BMC oral health · 2026