Medical journal, Armed Forces India

Comparative evaluation of clinical efficacy of two fixed functional appliances for treating skeletal class II malocclusion: A randomized controlled trial.

Saugat Ray, D C Chaudhary, Sanjeev Datana, Vishvaroop Nagpal, S S Agarwal

Reader & Instructor (Orthodontics & Dentofacial Orthopedics), Armed Forces Medical College, Pune, India. · Dental Officer & Classified Specialist (Orthodontics & Dentofacial Orthopedics), MDC Secunderabad, India.

Randomised

Key points

From the paper's conclusion
  • The authors conclude that post functional cephalometric changes for both the groups were similar. The duration taken for functional phase and time taken for appliance removal in Advansyc 2 was lesser than Forsus FRD.

Abstract

BACKGROUND: There exists limited literature on the comparison of Forsus fatigue-resistant device (Forsus FRD)TM and AdvansyncTM 2: The aim of this randomized Controlled Trial with Registration number CTRI/2021/01/030399, was to compare the clinical efficacy of Forsus FRD versus AdvanSync 2 in the treatment of Skeletal Class II malocclusion along with the differences in treatment duration, chairside time, patient comfort & operator's convenience and frequency of breakages of appliance. METHODS: Sixty samples after randomization were divided into two groups. Group I (Forsus FRD) and Group II (Advansync 2). The post functional cephalograms were taken (T1) and comparison of cephalometric data was done with pre-treatment records (T0). RESULTS: The differences between the cephalometric parameters at T0 and T1 were evaluated with Paired t- test. All the parameters showed statistically significant differences in both groups except SNA (in both Group I and II) and FMA (in Group II). Unpaired t-test reveals statistically insignificant differences between the groups except for lower lip protrusion with p = 0.001. Statistically significant reduction of the treatment time duration (p = 0.004) and chairside time for removal of appliance (p = 0.001) was observed. Mann Whitney U test was used for finding difference in operators' and patients' convenience and no statistically significant differences were observed between two groups. CONCLUSION: The authors conclude that post functional cephalometric changes for both the groups were similar. The duration taken for functional phase and time taken for appliance removal in Advansyc 2 was lesser than Forsus FRD.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparative evaluation of clinical efficacy of two fixed functional appliances for treating skeletal class II malocclusion: A randomized controlled trial — Science Skim