Analysis of the efficacy of AngelAligner A6 mandibular advancer and Twin Block in the treatment of class II malocclusion in growing patients: a prospective clinical study.
Giacomo Scuzzo, Giuseppe Scuzzo, Elena Calzadilla-Suárez, Mario Alvarado-Lorenzo, Laura Criado-Pérez, Adrián Curto, Alfonso Alvarado-Lorenzo
Eline Clinic Director, Piazza Gregorio Ronca, 38, Rome, 00122, Italy. · Department of Orthodontics, Università Cattolica del Sacro Cuore, Largo Francesco Vito, 1, Rome, 00168, Italy.
Key points
From the paper's conclusion- These findings suggest that the AngelAligner A6 MA and Twin Block are superior for skeletal correction, whereas the standard AngelAligner is effective for milder cases with aesthetic priorities.
Abstract
BACKGROUND: Although the twin block is the most commonly used appliance for the treatment of Class II malocclusion, the clear aligner industry has developed systems with integrated mandibular advancement. The purpose of this study was to evaluate and compare the effects of Twin block appliances, standard AngelAligner clear aligners and AngelAligner A6 mandibular advancement clear aligners as early orthodontic interventions for patients who develop Class II division 1 malocclusion. METHODS: The study sample comprised 60 patients with a mean age of 12.4 ± 1.3 years, who were divided into three homogeneous groups of 20 patients each and received different treatments: Twin Block (GTB), AngelAligner aligners (GAA) and AngelAligner A6 for mandibular advancement (GA6). Clinical and radiographic assessments were performed at baseline (T0), immediately prior to appliance placement, and repeated after the completion of treatment objectives (T1). RESULTS: Class II malocclusion was corrected with all three appliances. The GA6 and GTB groups showed similar mandibular advancement, with an increase in the SNB angle of 2.1° and 2.3° respectively, and correction to Class I in 85-90% of cases, outperforming the GAA group, which showed an increase in the SNB angle of 1.2° and correction to Class I in 70% of cases. The duration of treatment was shorter in the GA6 group (15.2 months). CONCLUSION: These findings suggest that the AngelAligner A6 MA and Twin Block are superior for skeletal correction, whereas the standard AngelAligner is effective for milder cases with aesthetic priorities. CLINICAL TRIAL NUMBER: ClinicalTrials.gov, NCT07591025. Registered 6 May 2026. Retrospectively registered.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical efficacy of aligners with mandibular advancement in treatment of Class II malocclusions compared to conventional functional appliances: A systematic review.Stomatologija · 2026
- Class II Malocclusion Correction Using “Distalizing Bar Appliances” and Clear Aligners: A Case Series and Clinical TechniqueDentistry Journal · 2026
- Management of Skeletal Class II Malocclusion in a Growing Patient Using Clear Aligners and Class II Elastics: A Case Report.Dentistry journal · 2026
- A comparative study of mandibular changes induced by rapid maxillary expansion vs sagittal-guided Twin-block therapy during the mixed dentition period.American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2026
- A Comparison of Clear Aligners and Fixed Appliances in Orthodontic-Surgical Treatment of Non-Extraction Skeletal Class III Malocclusion.Aesthetic plastic surgery · 2026
- Design Modifications of the Twin-Block Appliance: Facial and Dentoalveolar Outcomes in Class II Individuals.Dentistry journal · 2026