Medical image analysis

The autoPET3 challenge: Automated lesion segmentation in whole-body PET/CT - Multitracer multicenter generalization.

Jakob Dexl, Katharina Jeblick, Andreas Mittermeier, Balthasar Schachtner, Anna Theresa Stüber, Johanna Topalis, Maximilian Rokuss, Fabian Isensee,

Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany; Munich Center for Machine Learning (MCML), Munich, Germany. Electronic address: jakob.dexl@lmu.de. · Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany; Munich Center for Machine Learning (MCML), Munich, Germany; Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, Germany.

Computational

Key points

From the paper's conclusion
  • We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting.

Abstract

We report the design and results of the third autoPET challenge (MICCAI 2024), which benchmarked automated lesion segmentation in whole-body PET/CT under a compositional generalization setting. Training data comprised 1014 [18F]-FDG PET/CT studies from the University Hospital Tübingen and 597 [18F]/[68Ga]-PSMA PET/CT studies from the LMU University Hospital Munich, the largest publicly available annotated PSMA PET/CT dataset to date. The held-out test set of 200 studies covered four tracer-center combinations, two of which represented unseen compositional pairings. A complementary data-centric award category restricted participants to a fixed baseline model to isolate data handling strategies. Seventeen teams submitted 27 algorithms, predominantly nnU-Net-based 3D networks with PET/CT channel concatenation. The top-ranked algorithm achieved a mean DSC of 0.66, FNV of 3.18 mL, and FPV of 2.78 mL across all four test conditions, improving DSC by 8% and reducing the false-negative volume by 5mL relative to the provided baseline. Ranking was stable across bootstrap resampling and alternative ranking schemes for the top tier. Beyond the benchmark, we provide an in-depth analysis of segmentation performance at the patient and lesion level. Three main conclusions can be drawn: (1) in-domain multitracer PET/CT segmentation is sufficient and likely approaching reader agreement; (2) compositional generalization to unseen tracer-center combinations remains an open problem mainly driven by systematic volume overestimation; (3) heterogeneity and case difficulty drive performance variation substantially more than the choice of algorithm among top-ranked teams.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers